59
Replacement Checklists
Section 3-6
Checklist 7
Use the following checklist when replacing a 3G2A5-LK009 or C500-LK009-
V1 with a CVM1-LK401.
LR Area
LR 00 to LR 63
(LR 00 to LR 31 in C500)
LR 00 to LR 63
(LR 00 to LR 31 in C500)
---
PC Link Error
and PLC Run
Flags
SR 247 to SR 250/SR258
(SR 62 in C500)
SR 247 to SR 250/SR258
(SR 62 in C500)
Level Flags
Level #1
AR 2411
(Except C500)
Level #1
AR 2411
(Except C500)
Single-
level or
level #0
AR 2412
(Except C500)
Single-
level or
level #0
AR 2412
(Except C500)
PC Link Unit
Restart Bits
Level #1
SR 25210
(SR 6010 in C500)
Level #1
SR 25210
(SR 6010 in C500)
Single-
level or
level #0
SR 25214
(SR 6014 in C500)
Single-
level or
level #0
SR 25214
(SR 6014 in C500)
Item
Original Unit: 3G2A5-LK009
Replacement Unit: C500-LK009-V1
Remarks
Item
Original Unit: 3G2A5-LK009/C500-
LK009-V1
Replacement Unit: CVM1-LK401
Remarks
CPU Bus
Unit unit
number
Not applicable
Any unique number in setting
range (Do not set the same unit
number on two CPU Bus Units in a
PLC.)
Do not mount more PC
Link Units than allowed.
Node
address
Check setting on pins 1 to 5: [ ]
Set the CVM1-LK401’s node
address to the same node address
that was set on the 3G2A5-LK009/
C500-LK009-V1. Set the rotary
switches in 2-digit decimal.
If upgrading from a C500 PLC, set
a node address between 00 and
07.
Check the node address
settings on other nodes in
the PC Link to confirm
that the same address is
not already taken.
A Unit error will
not
occur
if the same node address
is set on two PC Link
Units in the same PC
Link, but there will be
data errors in the LR
Area.
Pins
1 to 5
Node
address
Pins
1 to 5
Node
address
00000
0
10000
16
00001
1
10001
17
00010
2
10010
18
00011
3
10011
19
00100
4
10100
20
00101
5
10101
21
00110
6
10110
22
00111
7
10111
23
01000
8
11000
24
01001
9
11001
25
01010
10
11010
26
01011
11
11011
27
01100
12
11100
28
01101
13
11101
29
01110
14
11110
30
01111
15
11111
31
NODE
No.
×
10
1
×
10
0
0
0
Содержание CVM1 Series
Страница 1: ...Cat No W434 E1 01 SYSMAC CVM1 CV Series CVM1 LK401 PC Link Unit This manual is PDF file only...
Страница 2: ...CVM1 LK401 PC Link Unit Operation Manual Produced July 2004...
Страница 3: ...iv...
Страница 5: ...vi...
Страница 41: ...26 Differences from Earlier PC Link Units Section 2 6...
Страница 77: ...62 Replacement Checklists Section 3 6...
Страница 95: ...80 Link Adapter Specifications Appendix B...
Страница 101: ...86 PC Link System I O Response Time Appendix C...
Страница 103: ...88 PC Link Settings and Status Areas Appendix D...
Страница 105: ...Revision History 90...