1 Introduction
1-10
CJ-series High-speed Counter Units Operation Manual for NJ-series CPU Unit(W492)
Additional Information
• Each Counter Input (A, B, Z) is insulated from the others and from the Digital Inputs. Each Dig-
ital Input is also insulated from the others.
• A noise filter can be configured to 10 kHz or 50 kHz (default) for the Digital Inputs. Every Z-
Input has a defined noise filter of 1 kHz.
• If the 50-kHz noise filter is configured for Digital Inputs, signals of 10
µ
s or longer can be read.
1-3-3
Input Specifications
Item
Counter Inputs A and B
Digital Inputs
(I0 and I1)
Input Voltage
24 VDC
(19.6 to 26.4 V)
12 VDC
(9.8 to 13.2 V)
5 VDC
(4.5 to 5.5 V)
Line Driver
24 VDC
(19.6 to 26.4 V)
Input Current
(typical)
8 mA
8 mA
7 mA
11 mA
Connectable to
RS-422 compati-
ble Line Drivers.
7.6 mA
ON Voltage (min.)
19.6 V
9.8 V
4.5 V
19.6 V
OFF Voltage
(max.)
4 V
2.5 V
1.5 V
4 V
Item
Counter Input Z
Input Voltage
24 VDC
(18.6 to 26.4 V)
12 VDC
(9.8 to 13.2 V)
5 VDC
(4.5 to 5.5 V)
Line Driver
Input Current
(typical)
7.3 mA
6.6 mA
6 mA
11 mA
Connectable to
RS-422 compati-
ble Line Drivers.
ON Voltage (min.)
18.6 V
9.8 V
4.5 V
OFF Voltage
(max.)
4 V
2.5 V
1.5 V
Содержание CJ1W-CT021
Страница 10: ...Manual Structure 8 CJ series High speed Counter Units Operation Manual for NJ series CPU Unit W492...
Страница 38: ...Revision History 36 CJ series High speed Counter Units Operation Manual for NJ series CPU Unit W492...
Страница 190: ...Appendicies A 18 CJ series High speed Counter Units Operation Manual for NJ series CPU Unit W492...
Страница 191: ...Index 1 CJ series High speed Counter Units Operation Manual for NJ series CPU Unit W492 I Index...
Страница 194: ...Index 4 CJ series High speed Counter Units Operation Manual for NJ series CPU Unit W492 Index...
Страница 195: ......