253
CPU Unit Error Indicators
Section 9-3
9-3-2
Useful Flags and Control Bits
Special I/O Unit Error
Flags
The PC error flags in the following tables will indicate the following errors.
• Duplicated unit numbers on Special I/O Units
• Refreshing between the CPU Unit and Special I/O Unit didn’t proceed
normally.
Note
*Of the C200HX/HG/HE CPU Units, used only in the C200HX/HG-CPU5
@
-
(Z)E C200HX/HG-CPU6
@
-(Z)E.
Special I/O Unit Restart
Bits
To restart a Special I/O Unit, toggle (OFF
→
ON
→
OFF) the corresponding
Restart Bit shown in the following table. These bits can be used to restart the
Unit without turning off the power supply.
Flag address
Function
C200H/HS
C200HX/HG/HE
CS1
Errors Unit
Number
Duplication
AR 0000
SR 28200
A41800
A41100
ON when an error occurred in Unit 0.
AR 0001
SR 28201
A41801
A41101
ON when an error occurred in Unit 1.
AR 0002
SR 28202
A41802
A41102
ON when an error occurred in Unit 2.
AR 0003
SR 28203
A41803
A41103
ON when an error occurred in Unit 3.
AR 0004
SR 28204
A41804
A41104
ON when an error occurred in Unit 4.
AR 0005
SR 28205
A41805
A41105
ON when an error occurred in Unit 5.
AR 0006
SR 28206
A41806
A41106
ON when an error occurred in Unit 6.
AR 0007
SR 28207
A41807
A41107
ON when an error occurred in Unit 7.
AR 0008
SR 28208
A41808
A41108
ON when an error occurred in Unit 8.
AR 0009
SR 28209
A41809
A41109
ON when an error occurred in Unit 9.
---
SR 28210
A41810
A41110
ON when an error occurred in Unit A (10).*
---
SR 28211
A41811
A41111
ON when an error occurred in Unit B (11).*
---
SR 28212
A41812
A41112
ON when an error occurred in Unit C (12).*
---
SR 28213
A41813
A41113
ON when an error occurred in Unit D (13).*
---
SR 28214
A41814
A41114
ON when an error occurred in Unit E (14).*
---
SR 28215
A41815
A41115
ON when an error occurred in Unit F (15).*
Model
Flag address
Function
C200HX/HG/HE(-Z)
C200H/HS
SR 25415
ON when an error occurred in a
Special I/O Unit.
CS1
A40206
A40113
ON with the same unit number
has been assigned to more
than one Special I/O Unit.
Bit address
Function
C200H/HS
C200HX/HG/HE
CS1
AR 0100
SR 28100
A50200 Restarts Unit 0.
AR 0101
SR 28101
A50201 Restarts Unit 1.
AR 0102
SR 28102
A50202 Restarts Unit 2.
AR 0103
SR 28103
A50203 Restarts Unit 3.
AR 0104
SR 28104
A50204 Restarts Unit 4.
AR 0105
SR 28105
A50205 Restarts Unit 5.
AR 0106
SR 28106
A50206 Restarts Unit 6.
AR 0107
SR 28107
A50207 Restarts Unit 7.
AR 0108
SR 28108
A50208 Restarts Unit 8.