12
Basic Operating Procedures
Section 1-6
1-6
Basic Operating Procedures
1-6-1
Editing BASIC Programs
The following example uses WINDOWS 95 on a personal computer as a ter-
minal (hyperterminal VT-100 emulation).
1,2,3...
1.
Mount the ASCII Unit to the Backplane. Refer to
2-2 Installation
.
2.
Connect the Unit’s terminal port to the personal computer’s RS-232C port
via an RS-232C cable. Refer to
2-2 Installation
.
3.
Set the switches on the front of the Unit.
4.
Turn on the PC power supply.
5.
Perform the following steps if the ASCII Unit’s default setup is used.
a)
Clear all the DM words allocated to the ASCII Unit in the CPU Unit us-
ing a PC Peripheral Device (such as a Programming Console).
b)
Toggle the PC power switch off and then back on, or restart the ASCII
Unit.
Inter-
rupts
PC interrupts
Using allocated IR/CIO
area words
Yes
Yes
---
Using IOWR (CC##)
instruction
None
Yes
---
Maximum number
15
99
---
Communica-
tions interrupts
(via received
data)
Interrupts when data is
received in the receive
buffer
Yes
Yes
---
Interrupt on reception
of designated character
None
Yes
---
Interrupt on reception
of designated number
of bytes
None
Yes
---
Interrupt on reception
of designated start and
end characters
None
Yes
---
Interrupt on reception
of designated start
character and desig-
nated number of bytes
None
Yes
---
Key interrupts
Yes
Yes
---
Timed interrupts
None
Yes
---
Interval timer interrupts
None
Yes
---
One-shot timer interrupts
None
Yes
---
Error interrupts
Yes
Yes
---
Line code storage command on interrupt
None
Yes (INTRB, INTRR,
INTRS)
---
Error log
None
Yes (Can record up to
30 error records.
Time and date of
occurrence not
recorded.)
---
Internal current consumption
5 VDC
200 mA
5 VDC
250 mA or 300 mA
Item
C200H-ASC02
C200H-ASC11
/ASC21/ASC31
Comments
Содержание C200H-ASC11
Страница 1: ...C200H ASC11 ASC21 ASC31 ASCII Units Operation Manual Revised June 2000...
Страница 2: ...iv...
Страница 4: ...vi...