6
Internal Configuration
Section 1-3
Data read/write that does not depend on the cycle time can be executed using
the IOWR (SPECIAL I/O UNIT WRITE) or IORD (SPECIAL I/O UNIT READ)
instructions from the CPU Unit (C200HX/HG/HE or CS1).
Interrupts that do not depend on the cycle time can be sent from the CPU Unit
to the ASCII Unit using IOWR (SPECIAL I/O UNIT WRITE) instructions
(C200HX/HG/HE or CS1).
Data Exchange
CPU Unit
ASCII Unit
Ladder program
BASIC program
Internal operation
Interrupt
Data exchange
with the CPU
Unit:
PC READ/
PC WRITE
PC READ@/
PC WRITE@
PC QREAD@/
PC QWRITE@
Data exchange
with general-
purpose periph-
eral devices:
OPEN#
PRINT#
INPUT#
INPUT$, etc.
Transmit
buffer
Receive
buffer
General-purpose
peripheral devices
I/O memory
Allocated words in IR/CIO
Area (Special I/O Unit Areas)
I/O refresh
Allocated I/O area
10 words allocated
per ASCII Unit
DM Area
Power ON or restart
Transfer YES/NO
Shared memory
Parameter Area
IORD/
IOWR Area
RS-232C or
RS-422/485
PC PUT
PC GET
PC EPUT
PC EGET
MOV, OUT, etc.
IOWR (#00
@@
/IORD#00
@@
)
IOWR (#FD00/IORD#FD00)
IOWR (#CC00)
:
:
:
:
:
:
:
:
n
n+4
n+5
n+9
n
n+4
n+5
n+9
0
9
10
99
m
m+9
m+10
m+99
Содержание C200H-ASC11
Страница 1: ...C200H ASC11 ASC21 ASC31 ASCII Units Operation Manual Revised June 2000...
Страница 2: ...iv...
Страница 4: ...vi...