1

The weight of the BHM60PC is 8.2 kg, and the weight of the BHM100PC is 10.3 kg.
Carefully consider the weight when unpacking/transporting this product.

 Injury may result if the unit falls or is dropped.

Do not disassemble, repair, or modify the product.

 Doing so may cause an electric shock or a fire.

Place the unit on a level, stable and solid surface. 

 Injury may result if the unit falls or is dropped.

 The weight of the unit is approximately: 

  BH60PCW(RE60FW): 6.3kg 

BH100PCW(RE100FW): 6.6kg

  Battery unit BHM60PC: 8.2kg 

Battery unit BHM100PC: 10.3kg

 If you drop the unit, stop using it and have it inspected and repaired. 

Keep plastic bags out of the reach of children. 

 Children may suffocate if they put their heads into plastic bags.

Do not use the product where the maximum temperature exceeds 55°C.

 The battery weakens rapidly, and may cause a fire.

 Doing so may cause the unit to fail or malfunction.

Do not use this product in applications which require an extremely high degree of 
reliability and safety, such as those listed below. 
(This product is designed and manufactured for use for FA/OA equipment such as personal computers.)

 Medical equipment or system that may cause death directly

 Applications that directly affect the safety of people. (For example, the operation and control of cars and elevators.)

 Applications in which failure may significantly damage or impact the society and public. (For example, important com

-

puter systems or communication equipment.)

 Applications with the same level of importance as those described above.

: Indicates a prohibited action (something you must not do). For example, 

 indicates that disas-

sembly is prohibited.

: Indicates a necessary action (something you must do). For example, 

 indicates that grounding 

is necessary.

This manual contains important information regarding the safe 
use of this product.
Please read these instructions before installation and/or use.

Warning

Caution

Safety precautions

 The safety symbols used in this manual are explained below.

  * Property damage means damage to houses/household effects, livestock, and pets.

Note that some items described as cautions may result in more serious damage under certain conditions.
The information described here is very important and must be strictly observed.

Warning (product use)

Caution (installation)

For the use of UPS BH60PCW/BH100PCW

 This manual contains important information regarding the safe use of the BHM60PC/BHM100PC for the Backup 

Power Supply BH60PCW/BH100PCW. Please read these instructions before installing and/or using the product.

 Please connect and install the battery unit only after having fully understood the relevant procedures for the 

Backup Power Supply, found in the Backup Power Supply BH60PCW/BH100PCW Instruction Manual.

Battery Unit BHM60PC/BHM100PC Instruction Manual

Indicates an imminently hazardous situation which, if not handled 
properly, may result in death or serious injury.
Indicates a potentially hazardous situation which, if not handled 
properly, may result in injury or property damage.

Содержание BHM100PC

Страница 1: ...portant com puter systems or communication equipment Applications with the same level of importance as those described above Indicates a prohibited action something you must not do For example indicates that disas sembly is prohibited Indicates a necessary action something you must do For example indicates that grounding is necessary This manual contains important information regarding the safe us...

Страница 2: ...s or is dropped Do not pinch or tie the cable of the unit Doing so may damage the cable or cause it to become hot resulting in an electric shock or a fire If the cable is damaged immediately stop using the unit and have it repaired All of the included accessories are designed to be used exclusively with the unit Do not use the accessories with other devices Doing so may compromise the safety of de...

Страница 3: ...instruction manual Ambient temperature Expected life 20 C 5 to 7 years 30 C 3 to 4 years 40 C 1 5 to 2 years 50 C 0 7 to 1 years Caution use Battery can be replaced while the unit is stopped only When replacing the battery stop the connected devices turn off the power supply UPS output switch and disconnect the AC input plug from the wall outlet Do not insert metal objects into the battery connect...

Страница 4: ...hase If you do not use the unit for a long time after purchase the battery performance may deteriorate and it may become un usable The battery can be charged once the AC input plug of the UPS is connected to a wall outlet commercial power When storing the UPS charge the battery and turn OFF the power switch The battery discharges even when it not being used and it goes into over discharge state if...

Страница 5: ...attery units can be connected Do not connect more than 2 units For information about units with no additional battery units connected refer to the BH100PCW BH60P CW instruction manual Correct positions Horizontal Vertical For vertical placement make sure to position in this way BH100PCW BHM100PC BHM100PC BHM100PC Incorrect positions Do not position the unit upside down Do not position the unit so ...

Страница 6: ...luded with the rack mount brackets BHP60J For details refer to the instruction manual included with the rack mount brackets BHP60P and support angles BUP06 Support angles are not compatible Use a server rack 2 2 Connecting the battery unit Up to 5 battery units can be connected to the 1kVA type BH100PCW Additional battery units also use the same model of BHM100PC for 1kVA as the first unit Use sup...

Страница 7: ...are a valuable recyclable resource Please recycle For information about recycling please contact our Electronic Systems Equipments repair center Be careful not to lose the screws that you remove 2 Disconnect the 2 battery connectors and loosen the 4 screws to remove the fixing bracket Press firmly on this part when removing Caution When an UPS is used in compliance with UL CE standards do not repl...

Страница 8: ... Be careful not to drop the battery 4 Insert the new battery and attach the fixing bracket Insert the battery with the label side facing upward wire is on right side 5 Connect the connectors Make sure the connector locks are firmly secured 6 Attach the front panel ...

Страница 9: ...the UPS monitoring software included with the UPS keep a record of the software usage start date This unit uses a lead acid battery ALead acid batteries are a valuable recyclable resource Please recycle For information about recycling please contact our Electronic Systems Equipments repair center Notes 4 Replacing the battery unit The UPS BH60PCW BH100PCW battery unit BHM60PC BHM100PC can be repla...

Страница 10: ...it After replacing the battery unit make sure to reconnect all of the disconnected cables Make sure the battery unit s built in battery connector in the front panel is connected If commercial power is supplied to the battery unit make sure the charging indicator on the battery unit s front panel is illuminated 3 When you finish connecting the battery press and hold the indicator selection switch o...

Страница 11: ...A Inverter unit Output filter Signal connection RS 232C Communication Interface External contact Interface Battery unit Charger Indicators BHM60PC BHM100PC BH60PCW RE60FW BH100PCW RE100FW Gate drive Digital controller Detection circuit NF Output 100 to 120 VAC A B C LED operation panel Step up Converter Circuit block diagram ...

Страница 12: ...12 K1L D 05100D Unauthorized reproduction of this manual in part or in whole is prohibited The contents of this manual are subject to change without notice OMRON Corporation 2006 All Rights Reserved ...

Отзывы: