background image

42

FCC STATEmENT

FCC CAUTION

Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

Note:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits 

are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate 

radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. 

However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio 

or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one 

or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

This device complies with Part 15 and Part 18 of FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause 

harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. 
This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) 

Exposure Guidelines. This equipment has very low levels of RF energy that are deemed to comply without testing of specific absorption ratio (SAR).

rEguLATOry COmpLIANCE INFOrmATION

Содержание Avail PM601

Страница 1: ......

Страница 2: ...of Storage Case And Pad Holder 13 Part Names And Functions of the Omron TENS App 14 Operating Instructions 16 Preparing for Use 16 Get Started with Your Therapy 19 Other App Features 28 How to Contro...

Страница 3: ...ister omron com You can also register your product via the Omron app Keep your purchase receipt as proof of purchase for warranty coverage The illustrations used in this manual are images Safety Instr...

Страница 4: ...or or other implanted metallic or electronic device Such use could cause electric shock burns electrical interference or death Receiving and Inspection Remove this device from the packaging and inspec...

Страница 5: ...plants e g heart pacemakers artificial heart lung or other electronic life support systems IP classification is degrees of protection provided by enclosures in accordance with IEC 60529 This device is...

Страница 6: ...into the chest may cause rhythm disturbances to your heart which could be lethal Do not place the pads near or on cancerous lesions diseased skin open wounds rashes swollen red infected or inflamed a...

Страница 7: ...ors ICDs Magnets are embedded in the storage case so that magnetism may affect pacemakers or ICDs Do not place the charger within 6 inches approx 15 cm to any person who is using pacemakers or implant...

Страница 8: ...d heart disease you should follow precautions recommended by your physician If you have suspected or diagnosed epilepsy you should follow precautions recommended by your physician Use caution if you h...

Страница 9: ...use inspect the cord for open wires or any damage If damaged do not use and replace immediately Clean and dry affected area so it is free of all lotions oils and sweat Clean or change the pad when it...

Страница 10: ...electrodes applied to your skin You may experience headache and other painful sensations during or following the application of electrical stimulation near your eyes and to your head and face You sho...

Страница 11: ...ses increase the production of the body s natural pain killer such as endorphins 3 Furthermore it is thought that electrical stimulation improves blood circulation About Microcurrent Therapy Microcurr...

Страница 12: ...11 Devices Pads Large Pad L Medium Pad M Storage Case and Pad Holder Instruction Manual Charger AC Adapter Package Contents Know Your Device...

Страница 13: ...green The device is connected to smartphone Blinks orange Battery is being recharged When the battery is fully charged the indicator light will go off Lit orange Battery is depleted Blinks white Ther...

Страница 14: ...he storage case 2 Remove the pad holder from the storage case and plastic bag 3 Attach the pad to the pad holder For more details refer to Storing the Pads on the Pad Holder on page 30 4 Place the pad...

Страница 15: ...l Battery charge is close to low 4 Displayed when there is any notification 5 Tap to show the therapy setting screen 6 Tap to show the pain diary screen to record your pain level or view your pain his...

Страница 16: ...For iPhone Tap to show the caption for app s display To close caption tap For Android 3 Tap to switch view orientation 4 Tap to change the mode 5 Tap to decrease intensity 6 Tap to increase intensity...

Страница 17: ...n start a session After the First Time Use 1 Open the Omron TENS app 2 Turn on the device 3 Select your body treatment area and place the pad on your skin 4 Select a mode and your therapy time then st...

Страница 18: ...and remove the devices from the charger Battery Life The rechargeable battery will last for up to 500 uses when fully charged and under the following conditions new battery was fully charged and used...

Страница 19: ...ce Which One Is Device A The device that is connected first will be referred to as device A on the app The second device that is connected will be referred to as device B Pairing Pairing Step 4 Attach...

Страница 20: ...n the Omron TENS app Confirm the device s is connected Make sure to always keep the smartphone near you during the session Treatment Area Selection 1 Tap on one of the suggested locations to select th...

Страница 21: ...hat the large pad is overlapped Do not apply any lotion cream or ointment to the pads Clean and dry affected area so it is free of all lotions oils and sweat Pads are for Single Patient Use Only Never...

Страница 22: ...int with pain LOWER BACK Place the pad on the lower back according to your pain For optimal therapy place the pad on the muscle of the lower back Do not place the adhesive surface of the pad on the sp...

Страница 23: ...INT KNEE Place so that the pad is above the knee or below the joint with pain Get Started with Your Therapy STEP 2 PAD PLACEMENT continued LEG CALF Place so that the pad is on the calf where you feel...

Страница 24: ...MENT continued SHOULDER Place so that pad is on the shoulder where you feel pain Do not place this device across your chest or near your heart because the introduction of electrical current into the c...

Страница 25: ...e this could cause severe muscle spasms resulting in closure of the airway difficulty in breathing or adverse effects on heart rhythm or blood pressure Do not use near the heart Do not place the pads...

Страница 26: ...utes MICROCURRENT 30 to 180 minutes 3 Tap SELECT 4 Tap START to start your session If you want to clear the therapy setting tap Clear Note If the session did not start check to make sure that The devi...

Страница 27: ...r intensity you may feel kneading or massage like sensations Recommended for Shoulder Low to medium rate tapping and pulsations Mode What does the therapy deliver Recommended for Joint Medium to high...

Страница 28: ...stop or interrupt the session tap QUIT White light on the device blinks during the session 2 When the session finishes press the power button on the device to turn off it Notes If your smartphone cann...

Страница 29: ...VORITE to repeat your favorite session 1 To save the current session tap The symbol will then change to 2 If you want to delete the current session from your favorite list tap The symbol will then cha...

Страница 30: ...day MICROCURRENT 30 minutes 180 minutes Unlimited Do not use this device to treat one region for extended periods of time The long term effects of electrical stimulation are unknown When a session is...

Страница 31: ...turned off Keep this device and pads out of the reach of infants toddlers and children Note With proper storage and use you may extend the life of your pads 1 Place the pad onto the pad holder A pad...

Страница 32: ...o remove extra water Wiping adhesive side of the pads with a soft cloth moistened with water may reduce their adhesive power Do not wash the pads with running water 3 Dry the pads and let the adhesive...

Страница 33: ...re using an another OS refer to your smartphone s instructions Try step 1 if any of the following situations occur There is no response when the device s power button is pressed You want to clear all...

Страница 34: ...o Pad Placement on page 20 and place correctly Is the adhesive surface of the pad worn out Replace the pad If this happens Possible causes Try this solution The device s power cannot be turned on Are...

Страница 35: ...urface of the pad Is the pad wet Or is your skin wet Air dry the adhesive surface of the pad or skin If this happens Possible causes Try this solution The adhesive side of the pad does not stick to sk...

Страница 36: ...there are no causes of transmission interference found near the device move the device within 16 ft 5 m of the smartphone and try again Was the Omron TENS app uninstalled and installed again Refer to...

Страница 37: ...3 Tap Contact Us 4 Select an issue and type the detail of your problem 5 Tap Send E mail Your email client app automatically opens 6 Send email 7 Our support stuff will respond to your email as soon a...

Страница 38: ...37 Accessories Large Pad PMWPAD L Medium Pad PMWPAD M AC Adapter HHP AM01 Approx 8 6 W 3 3 H 0 4 D 220 83 5 9 3 mm Approx 7 W 3 1 H 0 4 D 180 79 5 9 3 mm To order visit OmronHealthcare com...

Страница 39: ...on and Storage Between Uses Temperature Humidity 32 to 104 F 0 to 40 C 30 to 80 RH non condensing Temperature During Battery Charging 41 to 95 F 5 to 35 C non condensing Transportation Temperature Hum...

Страница 40: ...o change without notice About a wireless communication interference This Product operates in the unlicensed ISM band at 2 4 GHz In case this Product is used around the other wireless devices including...

Страница 41: ...charge any unit covered by the above warranty Replacement is our only responsibility and your only remedy under the above warranties To obtain warranty service contact Customer Service by calling 1 80...

Страница 42: ...COUNTRIES AND PROVINCES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU OMRON SHALL NOT BE LIABLE FOR LOSS OF USE OR ANY OTHER SPECIAL INCID...

Страница 43: ...er is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Conne...

Страница 44: ...m to this IEC60601 1 2 2014 standard for both immunity and emissions Nevertheless special precautions need to be observed The use of accessories and cables other than those specified by OMRON with the...

Страница 45: ...ns CISPR 11 Group 1 The PM601 uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emiss...

Страница 46: ...discharge 15 kV The relative humidity should be at least 5 Electrical fast transients bursts IEC 61000 4 4 Power supply lines 2 kV Longer input output lines 1 kV Power supply lines 2 kV Longer input o...

Страница 47: ...cycle 70 UT for 25 cycles 0 UT for 5 s Mains power quality should be that of a typical home commercial or hospital environment If user requires continued operation during power mains interruption insu...

Страница 48: ...t certain frequencies 3 V rms 150 kHz to 80 MHz 6 V rms The ISM bands and the amateur radio bands between 150 kHz to 80 MHz 10 V m 80 MHz to 2 7 GHz IEC 60601 1 2 2014 Table 9 Up to 28 V m at certain...

Страница 49: ...0 MHz the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people...

Страница 50: ...aration distance according to frequency of transmitter in meter 150 kHz to 80 MHz d 1 16 d 0 58 80 MHz to 800 MHz d 0 35 800 MHz to 2 7 GHz d 0 7 0 01 0 12 0 06 0 04 0 07 0 1 0 37 0 18 0 11 0 22 1 1 1...

Страница 51: ...China The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by OMRON HEALTHCARE Co Ltd is under license Other trademarks and trade names are...

Страница 52: ...For questions call 1 800 634 4350 Pads are for Single Patient Use Only OmronHealthcare com 3125420 0E...

Отзывы: