G-318
Safety Sensors / Components
Assembling the Cap
Emergency Stop Switch
Insert the protrusion of the Tightening Wrench (A22Z-3905) into the
Cap slot and then turn to remove the Cap.
Installing/Replacing the Lamp
Installing/Replacing from the Panel Surface
Insert the Lamp Extractor (A22Z-3901) into the lamp, then rotate the
Extractor while pressing it.
Installing/Replacing on the Switch
Grip the indicator with your fingers, then rotate the indicator while
pressing it against the Switch.
Control Box (Enclosure)
Mounting the Switch
The Standard-size Legend Plate Frame can be mounted. Mount the
Frame as shown in the following diagram. Mount the Switch in the
same way as for an ordinary panel.
Creating a Cable Port Hole
Place the tip of a screwdriver on the surface where the cable port
hole is to be created with the cover attached and strike the screw-
driver to punch a hole. Attempts to punch a hole on the other side of
the case will damage the Box.
Securing the Connector Cable
1.
Insert the connector into the cable port hole in the Box and secure
with the fixing nut inside the box.
2.
Open a hole in the thin rubber section of the rubber ring.
3.
Pass the tightening cap through the cable, insert the cable into
the connector, and tighten the hexagonal nut to secure the cable.
Cable diameter
Connector
7 to 9 dia.
A22Z-3500-1
9 to 11 dia.
A22Z-3500-2
Snap-in Legend Plate
Lock nut
Rubber washer
Connector
Tightening cap
Inside
Outside
Box
Cable