G-310
Safety Sensors / Components
Specifications
Approved Standards
Note:
UL-approved for CSA C22.2 No. 14 and bears the
c
R
mark.
Approved Standard Ratings
•
UL, cUL (File No. E41515)
6 A at 220 V, 10 A at 110 VAC
•
EN60947-5-1 (Low Voltage Directive)
Rated current: 10 A; Rated voltage: 220 VAC
Ratings
Contacts (Standard Load)
Note: 1.
Rated current values are determined according to the test-
ing conditions. The above ratings were obtained by con-
ducting tests under the following conditions.
(1) Ambient temperature: 20×±2°C
(2) Ambient humidity: 65±5%
(3) Operating frequency: 20 operations/minute
2.
Minimum applicable load: 10 mA at 5 VDC
Contacts (Microload)
LED Indicators without Voltage Reduction Unit
Super-bright LED Indicator
Incandescent Lamp
Voltage-reduction Lighting
Recognized
organization
Standards
File No.
UL (See note.)
UL508
E41515
AZCO
EN60947-5-1
C9805502
Rated
carry
current
Rated
voltage
Rated current (A)
AC15
(induc-
tive load)
AC12
(resistive
load)
DC13
(induc-
tive load)
DC12
(resis-
tive load)
10
24 VAC
10
10
---
---
110 VAC
5
10
220 VAC
3
6
380 VAC
2
3
440 VAC
1
2
24 VDC
---
---
1.5
10
110 VDC
0.5
2
220 VDC
0.2
0.6
380 VDC
0.1
0.2
Rated applicable load
Minimum applicable load
50 mA at 5 VDC
(Resistive load)
1 mA at 5 VDC
Rated voltage
Rated current
Operating voltage
6 VDC
60 mA
6 VDC±5%
6 VAC
60 mA
6 VAC/VDC±5%
12 VAC/VDC
30 mA
12 VAC/VDC±5%
24 VAC/VDC
15 mA
24 VAC/VDC±5%
Rated voltage
Rated current
Operating voltage
24 VAC/VDC
15 mA
24 VAC/VDC ±5%
Rated voltage
Rated current
Operating voltage
6 VAC/VDC
200 mA
5 VAC/VDC
14 VAC/VDC
80 mA
12 VAC/VDC
28 VAC/VDC
40 mA
24 VAC/VDC
130 VAC/VDC
20 mA
100 VAC/VDC
Rated voltage
Operational voltage
Applicable lamp
(BA9S/13
#
gold)
110 VAC
95 to 115 VAC
LED Lamp
(A22-24A
#
)
220 VAC
190 to 230 VAC