The connections for SSI are:
/i
fig. 148
The table below and the figure give an example of how to connect the
Stegmann ATM 60-A encoder to the TJ2-KS02.
/i
Encoder signal
Pin
DATA+
7
DATA-
8
CLOCK+
2
CLOCK-
3
+5V
6
0V
9
Note
The TJ2-KS02 does not have a termination inside. In case of long
distances or disturbed communication, add an external termina-
tion to the TJ2-KS02.
24 VDC Power Supply
24 V
0 V
7
8
2
3
9
2
TJ2-KS02
10
3
11
1
8
Encoder
TJ2-KS02
Pin
Signal
Wire color
Pin
Signal
2
DATA+
White
7
DATA+
10
DATA-
Brown
8
DATA-
3
CLOCK+
Yellow
2
CLOCK+
11
CLOCK-
Lilac
3
CLOCK-
1
GND
Blue
9
GND
8
Us
Red
See footnote
1
1. Use an external power supply