Hardware reference
HARDWARE REFERENCE MANUAL
236
Revision 5.0
Command Specifications
The following commands can be sent to the FQ-M to control its functions.
Example
The following example maps the FQ-M (address 1002) Command area to VR
locations 100 to 104 and the Response and Output area to VR locations 200
to 212:
ETHERCAT($66,0,1002,100,5,200,13)
As a result the Control word is mapped to VR(100), the Command word to
VR(101), etc..
The status of the FQ-M can be read from VR(200).
To read the ERR flag, use
READ_BIT(15,200)
Note
Please refer to the FQ-M User’s manual (Z314-E1) to configure
the Fieldbus Data Output.
Function
Command code
Start continuous measurement
$00101020
End continuous measurement
$00101030
Clear measurement values
$00102010
Clear Data Output Buffer
$00102020
Reset Encoder Counter
$00102030
Save Data in Sensor
$00103010
Re-register Model
$00104010
Reset
$0010F010
Get Scene Number
$00201000
Select Scene
$00301000
Get Inspection Item Data
$00401020
Set Inspection Item Data
$00501020
Get Software Version Information
$00403000
Get Encoder Counter
$00206000
Set Encoder Counter
$00306000