Hardware reference
HARDWARE REFERENCE MANUAL
192
Revision 5.0
The connections for SSI are:
/i
fig. 103
The table below and the figure give an example of how to connect the
Stegmann ATM 60-A encoder to the TJ1-FL02.
/i
Related BASIC commands
The following BASIC commands are related to SSI absolute encoders:
•
ATYPE (ATYPE=48)
•
ENCODER_BITS
For more information, refer to the Trajexia Programming Manual.
Encoder signal
Axis A
Axis B
DATA+
6
8
DATA-
7
9
CLOCK+
1
11
CLOCK-
2
12
GND
5 / 15
5 / 15
Note
The TJ1-FL02 does not have a termination inside. In case of long
distances or disturbed communication, add an external termina-
tion to the TJ1-FL02.
24 VDC Power Supply
24 V
0 V
6
7
1
2
5
2
TJ1-FL02
10
3
11
1
8
Encoder
TJ1-FL02
Pin
Signal
Wire color
Pin
Signal
2
DATA+
White
6
DATA+
10
DATA-
Brown
7
DATA-
3
CLOCK+
Yellow
1
CLOCK+
11
CLOCK-
Lilac
2
CLOCK-
1
GND
Blue
5
GND
8
Us
Red
See footnote
1
1. Use an external power supply