4. INSTALLATION
4.1 Attachment
Before attaching the speaker, make sure that the installation area can hold a minimum point load of 5 times
the speaker's weight.
The device must only be installed at a vibration-free, oscillation-free and fire-resistant location.
Please refer to the instructions under Operating Determinations.
The given minimum mounting depth must be kept to leave free space behind the speaker.
Please note:
when using this speaker system in public or industrial areas, a series of safety instructions
have to be followed that this manual can only give in part. The operator must therefore inform himself on the
current safety instructions and consider them.
Procedure:
Step 1:
Saw out a mounting hole with the correct mounting dimensions (see chapter Technical
Specifications).
Step 2:
Place the C-shaped backing plate aroung the mounting hole and secure the mounting brackets
onto the backing plate.
Step 3:
Make the electrical connection (section
4.3
).
Step 4:
Remove the protective grille.
Step 5:
Insert the speaker into the ceiling.
Step 6:
Fix the speaker cabinet by tightening the mounting screws. Insert the protective grille again.
Step 7:
Additionally, the speaker can be secured with a safety bond via the safety eyelet.