background image

Description

OmniConverter FPoE+/S

10/100BASE-T to 100BASE-X 

Fiber Media Converter with PoE+

Standard Compliances

IEEE 802.3, 802.3af (15.40 watts)
IEEE 802.3, 802.3at (30 watts)

PoE Supported Modes

IEEE Alternate A (Alt A)
IEEE Alternate B (Alt B)

Cisco Legacy and High Cap

Environmental

RoHS, WEEE and REACH

Frame Size

Up to 10,240 bytes

Port Types

Copper:  10/100BASE-T (RJ-45)
Fiber:      100BASE-X (ST, SC, SFP)
               100BASE-BX (SC, SFP)

Cable Types

Copper:   EIA/TIA 568A/B, 

                Cat 5 UTP and higher
Fiber:      Multimode: 50/125, 62.5/125µm
               Single-mode: 9/125µm

AC Power Requirements

(Models with AC/DC Adapters)

1 RJ-45 Port:
100 - 240VAC/47 to 63Hz

0.34A @ 120VAC (typical)

2 RJ-45 Ports:
100 - 240VAC/50 - 60Hz

0.63A @ 120VAC (typical)

DC Power Requirements
(Models with DC Terminals)

1 RJ-45 Port:
+/-48 to +/-57VDC;
0.74A @ 48VDC
3 Pin Terminal (isolated)

2 RJ-45 Ports:
+/-48 to +/-57VDC;
1.37A @ 48VDC
3 Pin Terminal (isolated)

A minimum DC input voltage of 50VDC is required to guarantee 25.5 

watts (for 802.3at) at the end of 100 meters on Cat 5 cable or better. 

Dimensions  (W x D x H)

4.5” x 6.0” x 1.0”  (114.3 mm x 152.4 mm x 25.4 mm)

Weight

Module:                                     1.1 lbs.  (498.9 grams)

Module with AC/DC Adapter:    2.3 lbs.  (1043.3 grams)

Operating Temperature
(See Temperature Derating Table)

Commercial:       0 to 50°C
Wide:               -40 to 60°C  (-20°C AC cold start)
Extended:        -40 to 75°C  (-20°C AC cold start)
Storage:           -40 to 80°C

Humidity 

5 to 95% (non-condensing)

Altitude 

-100m to 4,000m

MTBF (hrs) 

Module:                474,000
AC/DC Adapter:   100,000

Warranty

Lifetime warranty with 24/7/365 free Technical Support

Regulatory Compliances

(*Pending)

Safety: 

UL 62368-1*,

 

UL 60950-1,

 

IEC 62368-1*,

 

IEC 60950-1,

 

EN 62368-1*, 

 

EN 60950-1, 

 

CAN/CSA C22.2 No. 62368-1-14*, 

 

CAN/CSA C22.2 No. 60950-1,

 

CE Mark

EMC: 

EN 55032/EN 55024 CE Emissions/Immunity

EMI: 

CISPR 32, 

 

FCC 47 Part 15 Subpart B Class A

EMS: 

IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV, 

 

IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m, 

 

IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV (DC models), 

 

IEC 61000-4-4 EFT: Power: 1 kV; Signal: 1 kV (AC models),

 

IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV (DC models), 

 

IEC 61000-4-5 Surge: Power: 1 kV Line/Line; 2 kV Line/Gnd; 

 

  Signal: 2 kV (AC models),

 

IEC 61000-4-6 CS: Signal: 3 V, 

 

IEC 61000-4-8 ( Magnetic Field) 30A/m, 

 

IEC 61000-4-11 (Voltage Dips, interrupts)

IP Rating: 

IP20 Protection

Page 17

Page 18

Содержание OmniConverter FPoE+/S

Страница 1: ...omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective with th...

Страница 2: ...e European Community directive 2012 19 EU on waste electrical and electronic equipment WEEE which together with the RoHS Directive 2015 863 EU for electrical and electronic equipment sold in the EU af...

Страница 3: ...10 SW5 RJ 45 FDX HDX RJ 45 Mode of Operation AN 100 FDX The RJ 45 port is set to auto negotiation with the following modes advertised 100FDX 100HDX 10FDX 10HDX AN 100 HDX The RJ 45 port is set to auto...

Страница 4: ...Sourcing Compatibility Page 7 RJ 45 Pinout PoE Modes Alternative A Alternative B Legacy VoIP 1 Vport Positive 2 Vport Positive 3 Vport Negative 4 Vport Positive Vport Negative 5 Vport Positive Vport N...

Страница 5: ...e Up On position return to primary is enabled Switch 15 P1 P2 Redun Switch 16 Rtn P1 Function DOWN Off DOWN Off Non redundant mode normal mode DOWN Off UP On Non redundant mode normal mode UP On DOWN...

Страница 6: ...uit breaker Connect the power wires to the circuit breaker and switch the circuit breaker ON If any module are installed the Power LED will indicate the presence of power During the installation ensur...

Страница 7: ...wer LED Indicators Legend Indicator Description Pwr OFF Unit not powered Green ON Unit powered Amber ON Over temperature condition Power LED Indicators Fiber Port LED Indicators Legend Indicator Descr...

Страница 8: ...able is not applicable to models with DC Terminal The DC Terminal models will provide full PoE power over the operating temperature range of the module as long as the DC input power meets the requirem...

Страница 9: ...s W x D x H 4 5 x 6 0 x 1 0 114 3 mm x 152 4 mm x 25 4 mm Weight Module 1 1 lbs 498 9 grams Module with AC DC Adapter 2 3 lbs 1043 3 grams Operating Temperature See Temperature Derating Table Commerci...

Страница 10: ...Appendix A Link Modes Page 19 Page 20...