Rear View with DC Power Connector
NEVER ATTEMPT TO OPEN THE CHASSIS OR
SERVICE THE POWER SUPPLY. OPENING THE
CHASSIS MAY CAUSE SERIOUS INJURY OR DEATH.
THERE ARE NO USER REPLACEABLE OR
SERVICEABLE PARTS IN THIS UNIT.
WARNING!!!
4) Connect Cables
a. When using the SFP model, insert the SFP Fiber transceiver into the SFP
receptacle on the front of the module (see the SFP Data Sheet 091-17000-001
for supported Fast Ethernet transceivers).
NOTE: The release latch of the SFP Fiber transceiver must be in the closed
(up) position before insertion.
b. Connect an appropriate multimode or single-mode fiber cable to the fiber port
on the front of the module. It is important to ensure that the transmit (TX) is
attached to the receive side of the device at the other end and the receive
(RX) is attached to the transmit side. When using single-fiber (SF) models, the
TX wavelength must match the RX wavelength at the other end and the RX
wavelength must match the TX wavelength at the other end.
c. Connect the Ethernet 10/100 RJ-45 port via a Category 5 or better cable to an
external 10BASE-T or 100BASE-TX Ethernet device.
Page 13
5) Verify Operation
Verify the module is operational by viewing the LED indicators.
Power LED Indicators
Legend
Indicator
Description
Pwr
OFF
Unit not powered
Green - ON
Unit powered
Amber - ON
Over temperature condition
Power LED Indicators
Fiber Port LED Indicators
Legend
Indicator
Description
P1
OFF
No link
Green - ON
Port linked at 100Mbps
Green - Blinking at 10Hz Port data activity at 100Mbps
Green - Blinking at 1Hz
Port linked at 100Mbps and in redundant standby mode
Amber - Blinking at 1Hz
Port linked at 100Mbps and receiving Far End Fault Indicator
(FEFI)
FDX
OFF
Port is in half-duplex
Green - ON
Port is in full-duplex
Stat
OFF
Transceiver does not support digital diagnostics or no
transceiver (SFP) is installed
Green - ON
Transceiver (SFP) supports digital diagnostics and no alarm is
detected
Amber - ON
Transceiver (SFP) supports digital diagnostics and alarms are
present
P2
OFF
No link
Green - ON
Port linked at 100Mbps
Green - Blinking at 10Hz Port data activity at 100Mbps
Green - Blinking at 1Hz
Port linked at 100Mbps and in redundant standby mode
Amber - Blinking at 1Hz
Port linked at 100Mbps and receiving Far End Fault Indicator
(FEFI)
FDX
OFF
Port is in half-duplex
Green - ON
Port is in full-duplex
Stat
OFF
Transceiver does not support digital diagnostics or no
transceiver (SFP) is installed
Green - ON
Transceiver (SFP) supports digital diagnostics and no alarm is
detected
Amber - ON
Transceiver (SFP) supports digital diagnostics and alarms are
present
Fiber LED Indicators