DIP-switch Bank Locations

The table below provides a description of each DIP-switch position and function.

Switch

1 Fiber, 1 RJ-45

1 Fiber, 2 RJ-45

2 Fiber, 1 RJ-45

2 Fiber, 2 RJ-45

1

Port 1 Duplex Mode

Port 1 Duplex Mode

Port 1 Duplex Mode

Port 1 Duplex Mode

2

N/A

N/A

Port 2 Duplex Mode

Port 2 Duplex Mode

3

Port 2 RJ-45 

AUTO/MAN

Port 2 RJ-45 

AUTO/MAN

Port 3 RJ-45 

AUTO/MAN

Port 3 RJ-45 

AUTO/MAN

4

Port 2 RJ-45 Speed

(Only in MAN mode)

Port 2 RJ-45 Speed

(Only in MAN mode)

Port 3 RJ-45 Speed

(Only in MAN mode)

Port 3 RJ-45 Speed

(Only in MAN mode)

5

Port 2 RJ-45 Duplex

(Only in MAN mode)

Port 2 RJ-45 Duplex

(Only in MAN mode)

Port 3 RJ-45 Duplex

(Only in MAN mode)

Port 3 RJ-45 Duplex

(Only in MAN mode)

6

Pause Capability

Pause Capability

Pause Capability

Pause Capability

7

RJ-45 Port 2 PoE/PSE RJ-45 Port 2 PoE/PSE RJ-45 Port 3 PoE/PSE

RJ-45 Port 3 PoE/PSE

8

N/A

RJ-45 Port 3 PoE/PSE

N/A

RJ-45 Port 4 PoE/PSE

9

PSE Configuration Type  PSE Configuration Type PSE Configuration Type PSE Configuration Type

10

PSE Configuration Type PSE Configuration Type PSE Configuration Type PSE Configuration Type

11

N/A

N/A

PSE Configuration Type PSE Configuration Type

12

Link Mode Selection

Link Mode Selection

Link Mode Selection

Link Mode Selection

13

Link Mode Selection

Link Mode Selection

Link Mode Selection

Link Mode Selection

14

PSE Reset

PSE Reset

PSE Reset

PSE Reset

15

N/A

N/A

Redundant Fiber Link

Redundant Fiber Link

16

N/A

N/A

Return to Port 1

Return to Port 1

DIP-switch Definitions

SW1 and SW2:  F/O Duplex “FDX/HDX” DIP-switch

The module

 

supports  100BASE-FX  SFPs  and  fixed  fiber  transceivers.   These 

DIP-switches are used to configure the fiber duplex mode. Setting these 

DIP-switches to the Up “HDX” position facilitates a connection that supports 

Half-Duplex. Setting these DIP-switches to the Down “FDX” position facilitates a 

connection that supports Full-Duplex operation.

Page 5

SW3, SW4 and SW5 RJ-45 Configuration DIP-Switches

SW3

RJ-45

AN/MAN 

SW4

RJ-45 

100/10

SW5

RJ-45 

FDX/HDX

RJ-45 Mode of Operation

AN

100

FDX

The RJ-45 port is set to auto-negotiation with the following modes 

advertised:  100FDX, 100HDX, 10FDX, 10HDX

AN

100

HDX

The RJ-45 port is set to auto-negotiation with the following modes 

advertised:  100HDX, 10FDX, 10HDX

AN

10

FDX

The RJ-45 port is set to auto-negotiation with the following modes 

advertised:  10FDX, 10HDX

AN

10

HDX

The RJ-45 port is set to auto-negotiation advertising 10HDX.

MAN

100

FDX

The RJ-45 port is set to manual negotiation and is forced to 100FDX.

MAN

100

HDX

The RJ-45 port is set to manual negotiation and is forced to 100HDX.

MAN

10

FDX

The RJ-45 port is set to manual negotiation and is forced to 10FDX.

MAN

10

HDX

The RJ-45 port is set to manual negotiation and is forced to 10HDX.

RJ-45 Port Configuration Matrix

SW6 - Pause  “On/Off” DIP-Switch

In auto-negotiation mode, setting this DIP-switch to the Up “On” position allows the 

unit to advertise Symmetrical and Asymmetrical Pause capability.  In auto-negotiation 

mode, setting the DIP-switch to the Down “Off” position allows the unit to advertise 

no Pause capability.  In the manual mode, this DIP-switch determines the Pause 

behavior.

SW7 - Power Sourcing Function, RJ-45 Port 

The module automatically detects the attached PD and provides the equipment 

with the necessary power.

This DIP-switch controls the power sourcing function for Port 2 on the single-fiber 

models and Port 3 on all other models (see DIP-switch Definition table on page 

5).  When this DIP-switch in the Down “On” position, the power sourcing function 

is enabled.  When the DIP-switch is in the Up “Off” position, the power sourcing 

function is disabled.

Switch Position

Description

DOWN

UP

7

RJ-45 Port 2 or 3 PoE/PSE 

Enabled (ON)

Disabled (OFF)

8

RJ-45 Port 3 or 4 PoE/PSE 

Enabled (ON)

Disabled (OFF)

Power Sourcing Function

SW8 - Power Sourcing Function, RJ-45 Port 

This DIP-switch controls the power sourcing function for the 2nd RJ-45 port on 

the 2 RJ-45 port models (see DIP-switch Definition table on page 5).  When this 

DIP-switch in the Down “On” position, the power sourcing function is enabled.  When 

the DIP-switch is in the “Off” UP position, the power sourcing function is disabled.

Page 6

Содержание OmniConverter FPoE+/S

Страница 1: ...omnitron systems com support within ninety 90 days from the date of shipment During the warranty period Omnitron will at its option repair or replace a product which is proven to be defective with th...

Страница 2: ...e European Community directive 2012 19 EU on waste electrical and electronic equipment WEEE which together with the RoHS Directive 2015 863 EU for electrical and electronic equipment sold in the EU af...

Страница 3: ...10 SW5 RJ 45 FDX HDX RJ 45 Mode of Operation AN 100 FDX The RJ 45 port is set to auto negotiation with the following modes advertised 100FDX 100HDX 10FDX 10HDX AN 100 HDX The RJ 45 port is set to auto...

Страница 4: ...Sourcing Compatibility Page 7 RJ 45 Pinout PoE Modes Alternative A Alternative B Legacy VoIP 1 Vport Positive 2 Vport Positive 3 Vport Negative 4 Vport Positive Vport Negative 5 Vport Positive Vport N...

Страница 5: ...e Up On position return to primary is enabled Switch 15 P1 P2 Redun Switch 16 Rtn P1 Function DOWN Off DOWN Off Non redundant mode normal mode DOWN Off UP On Non redundant mode normal mode UP On DOWN...

Страница 6: ...uit breaker Connect the power wires to the circuit breaker and switch the circuit breaker ON If any module are installed the Power LED will indicate the presence of power During the installation ensur...

Страница 7: ...wer LED Indicators Legend Indicator Description Pwr OFF Unit not powered Green ON Unit powered Amber ON Over temperature condition Power LED Indicators Fiber Port LED Indicators Legend Indicator Descr...

Страница 8: ...able is not applicable to models with DC Terminal The DC Terminal models will provide full PoE power over the operating temperature range of the module as long as the DC input power meets the requirem...

Страница 9: ...s W x D x H 4 5 x 6 0 x 1 0 114 3 mm x 152 4 mm x 25 4 mm Weight Module 1 1 lbs 498 9 grams Module with AC DC Adapter 2 3 lbs 1043 3 grams Operating Temperature See Temperature Derating Table Commerci...

Страница 10: ...Appendix A Link Modes Page 19 Page 20...

Отзывы: