RJ-45 Port Indicators
Legend
Indicator
Description
10
OFF
No link
Green - ON
Port linked at 10Mbps
Green - Blinking at 10Hz Port data activity at 10Mbps
Amber - Blinking at 1Hz
Port linked at 10Mbps and receiving AN Remote Fault
100
OFF
No link
Green - ON
Port linked at 100Mbps
Green - Blinking at 10Hz Port data activity at 100Mbps
FDX
Green - ON
Port is configured for full-duplex via DIP-switch or has
negotiated to full-duplex in AN mode
OFF
Port is configured for half-duplex via DIP-switches or Port 2 has
negotiated to half-duplex in AN mode or Port 2 in AN mode has
not established the correct connection
PSE
Green - ON
Port PSE is active
Amber - ON
Port PSE inactive
Amber - Blinking at 1Hz
Port PSE inactive due to resistance too low (< 15k ohms) or
short circuit detected
Amber - Blinking at 10Hz Port PSE inactive due to resistance to high (33k to 500k ohms)
OFF
Port PSE disabled
RJ-45 LED Indicators
Specifications
AC/DC Adapter Temperature Derating
Total Available Wattage to RJ-45 Ports
Model
RJ-45 Ports
Watts
Required
40
°C
50
°C
60
°C
70
°C
75
°C
FPoE/S
1
15 watts
Full Power
Full Power
Full Power
Full Power
Full Power
2
30 watts
Full Power
Full Power
Full Power
Full Power
Full Power
FPoE+/S
1
30 watts
Full Power
Full Power
Full Power
Full Power
Full Power
2
60 watts
Full Power
Full Power
Full Power
Full Power
50 watts
The AC/DC Adapter Temperature derating table is not applicable to models with DC Terminal.
The DC Terminal models will provide full PoE power over the operating temperature range of
the module as long as the DC input power meets the requirements stated in the specification
table.
Page 15
Page 16
Description
OmniConverter FPoE/S
10/100BASE-T to 100BASE-X
Fiber Media Converter with PoE
Standard Compliances
IEEE 802.3, 802.3af (15.40 watts)
PoE Supported Modes
IEEE Alternate A (Alt A)
IEEE Alternate B (Alt B)
Cisco Legacy and High Cap
Environmental
RoHS, WEEE and REACH
Frame Size
Up to 10,240 bytes
Port Types
Copper: 10/100BASE-T (RJ-45)
Fiber: 100BASE-X (ST, SC, SFP)
100BASE-BX (SC, SFP)
Cable Types
Copper: EIA/TIA 568A/B,
Cat 5 UTP and higher
Fiber: Multimode: 50/125, 62.5/125µm
Single-mode: 9/125µm
AC Power Requirements
(Models with AC/DC Adapters)
1 RJ-45 Port:
100 - 240VAC/47 to 63Hz
0.21A @ 120VAC (typical)
2 RJ-45 Ports:
100 - 240VAC/50 - 60Hz
0.36A @ 120VAC (typical)
DC Power Requirements
(Models with DC Terminals)
1 RJ-45 Port:
+/-46 to +/-57VDC;
0.46A @ 48VDC
3 Pin Terminal (isolated)
2 RJ-45 Ports:
+/-46 to +/-57VDC;
0.79A @ 48VDC
3 Pin Terminal (isolated)
Dimensions (W x D x H)
4.5” x 6.0” x 1.0” (14.3 mm x 152.4 mm x 25.4 mm)
Weight
Module:
1.1 lbs. (498.9 grams)
Module with AC/DC Adapter: 1.6 lbs. (725.7 grams)
Operating Temperature
(See Temperature Derating Table)
Commercial: 0 to 50°C
Wide: -40 to 60°C (-20°C AC cold start)
Extended: -40 to 75°C (-20°C AC cold start)
Storage: -40 to 80°C
Humidity
5 to 95% (non-condensing)
Altitude
-100m to 4,000m
MTBF (hrs)
Module: 474,000
AC/DC Adapter: 100,000
Warranty
Lifetime warranty with 24/7/365 free Technical Support
Содержание OmniConverter FPoE+/S