ERP Specifications
Configuring ERP
page 11-2
OmniSwitch AOS Release 7 Network Configuration Guide
June 2013
ERP Specifications
The following table specifies the
ERP
related specifications:
ITU-T G.8032 03/2010
Ethernet Ring Protection version 2
(Multi Rings and Ladder networks supported)
(Hold off timer, Lockout , Signal degrade SD, RPL
Replacement, Forced Switch, Manual Switch, Clear for
Manual/Forced Switch, Dual end blocking not supported)
ITU-T Y.1731/IEEE 802.1ag
ERP packet compliant with OAM PDU format for CCM
Supported Platforms
OmniSwitch 10K, 6900
Maximum number of rings per node
64
Maximum number of ring ports per node
128 (should this even be mentioned?)
Maximum number of nodes per ring
16 (recommended)
Maximum number of VLANs per port.
4094
Range for ring ID
1 - 2147483647
Range for remote MEPID
1 - 8191
Range for wait-to-restore timer
1 - 12 minutes
Range for guard timer
1 - 200 centi-seconds