$JOFF
This command allows you to turn off all data messages being output
through the current or other port, including any binary messages,
such as Bin95 and Bin96, etc.
This command has the following layout:
$JOFF[,OTHER]<CR><LF>
When the ‘,OTHER’ data field is specified (without the square
brackets), this command will turn off all messages on the other port.
There are no variable data fields for this message.
The receiver will reply with the following response:
$>
$JAPP
This command allows you to request the receiver for the currently
installed applications and to choose which application to use.
The receiver, by default, comes pre-installed with WAASRTKB
(SBAS) in application slot 1 and a second application, OMNIHP, in
application slot 2.
To poll the receiver for the current applications, send the following
message:
$JAPP<CR><LF>
The receiver will reply with the following response:
$>JAPP,OMNIHP,WAASRTKB,2,1
1 and 2 indicate which application slot is currently being used.
In the example above the OMNIHP application is in slot 2 and is
currently being used. The WAASRTKB application is in slot 1
To change from the current application to the other application,
when two applications are present, issue the following command:
$JAPP,OTHER<CR><LF>
or
$JAPP,APP<CR><LF>
The variable “APP” may be one of the following by name:
LBAND, WAAS, AUTODIFF, LOCDIF (local differential rover),
RTKBAS (local differential base)