![OmniSTAR 5220HP Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/omnistar/5220hp/5220hp_user-manual_739863041.webp)
OmniSTAR 5220HP User Manual
Issue 1.32 12/2010
41
$JT
This command displays the type of receiver engine within the
receiver module.
This command has the following layout:
$JT<CR><LF>
The receiver will (for example) output the following data:
$>JT,DF2g,MX31rev=29
The following table gives a description of the output:
JT
message header
DF2g
Dual Frequency second generation
MX31rev=29
Manufacturer hardware revision
$JAGE
This command allows you to choose the maximum allowable age for
correction data. The default setting is 2700 seconds. However this is
overruled by the OmniSTAR HP process which sets the maximum
allowable differential age to 300 seconds.
This command has the following layout:
$JAGE,AGE<CR><LF>
The variable
AGE
is the maximum differential age timeout in seconds.
‘
AGE
’ may be set to a value of 6 seconds or more.
The receiver will reply with the following response:
$>