background image

Connect one end of one of the pieces of the white plastic tub-
ing to the end of the faucet stem; See Figure 3.

1. Firmly push the poly tubing all the way into the faucet stem until

firmly seated.

NOTE:

The faucet stem has a quick connecting fitting (See Figure

4).  If you need to remove the water line (poly tubing) from the
quick connecting fitting, simply push in the collet ring while gen-
tly pulling the poly tubing out of the fitting. See Figure 4.

Install the saddle valve; See Figure 5.

1. Locate and turn off the cold water shut off valve.
2. Install the saddle valve on the cold water line as shown in 

Figure 5.

NOTE:

The saddle valve clamps onto soft or hard tubing or pipe

from 3/8” to 1-5/16” diameter. It will make its own hole in cop-
per tubing, but not in iron or brass. For brass or galvanized iron
pipe, drill a 5/32” hole in the pipe before mounting the saddle
valve.

Risk of electric shock. 

If possible, use a hand or

cordless drill when drilling the water pipe. If using an electric drill, be
sure that drill, cord and outlet are all properly grounded.
Be sure the water supply to cold the water line is turned off.

NOTE:

Do not turn the handle before installing or while installing

the saddle valve. To prevent damage to the piercing needle, make
sure the piercing needle does not project beyond the rubber gasket.

a. Clamp the saddle valve onto the copper tube with the screws

supplied.

b. Tighten the screws evenly and firmly, keeping the halves of

the bracket parallel.

c. When the clamp is tight, turn the valve handle clockwise to

pierce the supply line.

NOTE:

Leave the handle in this position (valve closed) until the filter

installation is complete.
3. The filter cartridge comes preassembled in the filter housing. See

Figure 6 for the filter cartridge components.

4. Install the two threaded compression fittings in the Filter

Housing. See Figure 7.

5. Screw the fittings into the “IN” and “OUT” ports of the filter

housing. Use a wrench and tighten the two fittings into the filter
housing head. 

NOTE:

The “IN” and “OUT” ports are marked on

the top of the filter housing.

2

3705 0600 CBF1

Faucet Stem
with Quick
Connecting
Fitting

Insert the 
Plastic Tubing
into Faucet Stem

Collet
Ring
Supply
Tubing

Figure 3

"OUT" Port

3/8" x 1/4"
Compression
Fittings

"IN" Port

Figure 7

Push down
on the collet
ring and pull
the tubing out.

Collet
Ring

Figure 4

Cold Water Valve

Cold Water Line

Saddle Valve Clamps

Piercing Needle

Valve Handle

TURN OFF the Cold Water
Supply with the Shut Off Valve.

Rubber Gasket

3706 0600 CBF3

Figure 5

"Head" Portion
of Filter Housing

Filter Housing
is ready for use

"Sump" Portion
of Filter Housing

CBF1 Filter Cartridge
comes preassembled
in the Housing

Figure 6

Содержание CBF1 A Series

Страница 1: ...use Change the filter cartridge if changes in taste color or flow of water occur This filter is not a water purifier and is not intended for use with contaminated water Comply with all state and loca...

Страница 2: ...needle make sure the piercing needle does not project beyond the rubber gasket a Clamp the saddle valve onto the copper tube with the screws supplied b Tighten the screws evenly and firmly keeping the...

Страница 3: ...the Water 1 Open the filter faucet and then slowly open the cold water shut off valve 2 To remove the air from the filter run the water for 30 minutes until the water runs clear NOTE Some trapped air...

Страница 4: ...et Screws 2 3 3 8 1 4 Compression Fittings 2 4 Head Assembly 1 5 Tank O Ring 1 6 Filter Cartridge Model CB1 1 7 Sump Tank 1 8 Saddle Valve Kit 1 9 1 4 Brass Insert 3 10 1 4 Compression Sleeve 2 11 1 4...

Страница 5: ...laisser couler pendant 10 secondes Remplacer la cartouche d s que l on remarque un changement du go t de l odeur ou du d bit de l eau Ce filtre n est pas un purificateur d eau et il ne doit pas tre ut...

Страница 6: ...riers poser le robinet vanne sur le tube en cuivre l aide des vis fournies b Serrer uniform ment et fermement les vis en gardant les moiti s des triers parall les c Lorsque les triers sont bien serr s...

Страница 7: ...ou jusqu ce qu elle coule bien claire NOTA Au cours des premiers jours d utilisation du robinet il se peut que de l air s en chappe 3 S assurer qu aucun des raccords ne fuient Pour tout autre renseign...

Страница 8: ...po 1 4 de po 2 4 T te du filtre 1 5 Joint torique de la cuve 1 6 Cartouche filtrante Mod le CB1 1 7 Cuve 1 8 Robinet vanne triers complet 1 9 Embout en laiton de 1 4 de po 3 10 Manchon compression de...

Страница 9: ...ambie el cartucho si observa cambios en el sabor el color o en el caudal del agua Este filtro no es un purificador de agua y no ha sido dise ado para ser usado con agua contaminada Cumpla con todas la...

Страница 10: ...era est firme gire el mango de la v lvula hacia la derecha para perforar la tuber a de suministro NOTA Deje el mango en esta posici n v lvula cerrada hasta que se haya completado la instalaci n del fi...

Страница 11: ...eje correr el agua unos 30 minutos hasta que corra limpia y transparente NOTA Puede que haya un poco de aire atrapado durante los primeros d as de funcionamiento 3 Verifique que no hayan fugas en los...

Страница 12: ...resi n de 3 8 1 4 2 4 Unidad de cabezal 1 5 Aro t rico del tanque 1 6 Cartucho del filtro Modelo CB1 1 7 Tanque de dep sito 1 8 Juego de v lvula de silla 1 9 Inserci n de lat n de 1 4 3 10 Manguito de...

Отзывы: