“Network address” (1 to 254) – set the network address for the Omnicomm LLS fuel
level sensor. When several sensors are connected to one external device, they should
have unique network addresses.
“Maximum reading” (1 to 4095) – select the maximum reading for the LLS fuel level
sensor. Default value – 4095.
“Minimum reading” (0 to 1023) – select the minimum reading for the LLS fuel level
sensor. Default value – 0.
“Filtration” – set the output signal filtration parameters:
“None”– no filtration is performed. This option is used, when filtration is carried out
by external device.
“Minimum”– this filtration is used in stationary fuel storages and non-mobile
machinery
“Medium”– this filtration is used in case of vehicle's operation in normal road
conditions
“Maximum”– this filtration is used in case of vehicle's operation in severe road
conditions
“Automatic data output”– select:
“No output” – no independent data output (without request) is performed
“Binary” – independent binary data output
“Character” – independent character data output
“Data output interval” (1 to 255 seconds) – set the independent data output interval
Automatic data output mode may be used only with maximum one Omnicomm LLS 4
sensor connected to one interface.
“Severe operating conditions” mode – switch on to enable additional filtration of
measurement values taking into account the rough working conditions.
“Data rate” – select the rate for data exchange with external device. Default value –
19,200 bit/s.