Specifications
Parameters
Value
Power supply voltage, V
7 – 80
Power consumption, W
0,4
Measurement range, mm
0…700, 1000, 1500, 2000,
2500, 3000
Main reduced error of measurement of the sensor, %
±1
Relative humidity at 25 °С (without moisture condensation),
%
From 5 to 95
Atmospheric pressure, kPa
From 84 to 107
Maximum relative humidity at 25 °С (without moisture
condensation), %
100
Working temperature range, °С
From - 60 to + 85
Body protection rating
IP69k
Operating mode
Continuous
Internal filter size
From 0 to 30
Measurement time period, s
1
Overall dimensions, cm
78×74×(24+length of
measuring piece)
Specifications
Omnicomm LLS 4 Fuel Level Sensors
4