EN
27
Electronic version
• When installed, the sensor should not be in contact with
reinforcement ribs and auxiliary equipment inside the tank
Installation of two sensors in one tank allows for a significant
reduction of the fuel level dependence on the vehicle inclination
angle (Figure 2).
2. Steam out the tank to ensure compliance with the safety rules
3. Drill a central opening and four mounting holes as described in
the user manual
Cut of the Sensor for a Specific Fuel Tank
1. Cut the sensor measuring part, considering the following
recommendations:
• the length of the measuring part should be 20 mm less than the
tank depth
• REF channel should be shorter than the sensor measuring part by
min 100 mm. If the difference is below 100 mm, cut REF channel
according to Figure 3.
2. Place the centering wall inside the measuring probe of the sensor
at a depth of 1 cm
Figure 2. Installation location for two Omnicomm LLS-Ex 5 sensors
Содержание LLS-Ex 5
Страница 42: ...РЕДАКЦИЯ 26 10 2021 EDITION ...