• “No” – no filtration is performed. This option is used when the
filtration is carried out by an external device.
• «Minimum» filtration is used when the device is installed in
stationary fuel storages and non-mobile machinery
• «Medium» filtration is used when the vehicle operates under
normal road conditions
• «Maximum» filtration is used when the vehicle operates under
harsh road conditions
“Data exchange rate” – select the rate for data exchange with
external devices. (Default value – 19200 bit/sec).
“Automatic data output” – select:
• “Disabled” – no independent data output (without request) is
performed
• “Enabled” – independent binary data output
“Data output interval” (1 to 255 seconds) – set the automatic data
output interval.
The automatic data output mode can be used only when not more
than one Omnicomm LLS-Ex 5 sensor is connected to one interface
and using exclusively the LLS protocol.
«Compensate for thermal expansion of fuel» – check the box to
disable tracking fuel level changes due to temperature fluctuations
(when the «Automatic adjustment» parameter is switched on).
«Compensation algorithm threshold» – when this value of the
difference in sensor readings is reached, the automatic adjustment
function is triggered. Default value - 200.