EN
24
Electronic version
Parameter
Value
Digital code range corresponding to
the maximum level measurement
value
1...4095
Digital code range corresponding
to the minimum level measurement
value
0...4094
Temperature measuring range
From - 40 to + 80 °C
Measurement time period
1 sec
Automatic data output interval
From 1 to 255 sec
Overall dimensions
87,3 × 83,5 × (21+length of the
measuring probe)mm
Weight, not more than
2 kg
Average service life before sensor
failure, hours, not less than
100 000
Average service life
12 years
* The reported accuracy is guaranteed when working with the fuel for
which the calibration was performed or when using the auto-tuning
function when filling the tank to the full
Electrical parameters of intrinsic safety
Table 2.
Parameter name
Value
Maximum input voltage Ui
6.95 V
Maximum input current Ii
0.46 А
Maximum internal capacity Ci
10 µF
Maximum internal inductance Li
50 µH
Ambient temperature
From - 40 to + 60 °C
Содержание LLS-Ex 5