8
Audio I/O Level Display
Either input or output levels can be displayed on the top 2 (L & R) meters. The highest LED illuminated indicates
digital sample-accurate peak signal levels. The meters are calibrated in decibels below full scale
digital (0 dBFS) in
2dB steps. 0 dBFS is the absolute maximum level in the digital domain. Levels from
–
34 dBFS to
–
14 dBFS are
displayed in blue, levels from –12 to –
2 dBFS are displayed in yellow and 0 dBFS (the clipping point) is displayed
in red. The b
ottom meter displays the composite MPX signal level referenced to 100% modulation
(FM Style Only)
.
Audio I/O Level Display
Processing Meter Display
In “Meter Display” Mode the vertical bargraphs show all of the processing activity (the amount of gain reduction) in
the AGC, Limiter and Clipper sections within the Omnia ONE.
(varies with style)
If the
“Menu Display” is
currently showing on the Omnia ONE
’s LCD screen, press and hold the jog
-wheel for two seconds to switch to the
processing meter display as shown below.
To return to the Menu display, simply click the jog wheel once. (See “
Using the Jog Wheel
” on Page 10)
Processing Meter Display
AGC Meters
Limiter/Clipper Meters
W…... Wide Band AGC L….. Low Band Limiter
L……. Low Band AGC
M…. Mid Band Limiter
M…… Mid Band AGC
P…... Presence Band Limiter
P…… Presence Band AGC
H….. High Band Limiter
H…… High Band AGC B….. Bass Clipper
M…. Main Clipper
(AM & FM Styles)
or F…..Final Limiter (MC & SP Styles)
Important Notes:
•
A solid white bar will drop downward from the top to display the amount of gain reduction in each
processing band. The
change from a solid bar to a checkerboard pattern indicates a “gated” condition
in that band.