CONFIGURATION MENU

 

To enter the 

CONFIGURATION MENU

, press and hold 

and

 

 

buttons for 3 seconds.

 

 

Parameter 

Set-up Information 

SEt ZEro 

 

PRESS 

 TO SKIP TO NEXT MENU ITEM 

PRESS 

 

TO SET A NEW SYSTEM ZERO 

 

This allows the user to introduce a fixed offset to the display value. The 

GROSS and NET values are then displayed with this offset taken into account. 
 

Values between 

-9999999

 and 

+9999999

 can be entered, using the 

 and 

 buttons to select a digit and the 

 and 

 buttons to increment or 

decrement the digits. Press 

 to accept the value and move onto the next 

parameter. 

 

SEt rAtE

 

 

PRESS 

 TO SKIP TO NEXT MENU ITEM 

PRESS 

 

TO CHANGE THE UPDATE RATE 

 

This allows the user to set the display update rate. The options available are 

the update rates of the display in Hz. Please note that the 25Hz update is only 

available in 

PEAK

 or 

TROUGH

 mode. 

 

When you choose to change the update rate, you will be prompted whether 

you want to select 25Hz. If you do not, press 

. You will then be prompted to 

select any of the other values which, in order, are 10Hz, 3Hz, 1Hz, 0.5Hz. To 

set the update rate for the value you want, press

 

SEt 

OUEr

 

 

PRESS 

 TO SKIP TO NEXT MENU ITEM 

PRESS 

 

TO SET OVERLOAD ALARM 

 

This allows the setting of a visual overload. The value entered is the display 

value at which the TR150 flashes 

OUErLOAd

 

Values between 

-9999999

 and 

+9999999

 can be entered, using the 

 and 

 buttons to select a digit and the 

 and 

 buttons to increment or 

decrement the digits. Press 

 to accept the value and move onto the next 

parameter. 
 

 

UK / Europe Office 
Tel: +44 (0)8700 434040  
Fax: +44 (0)8700 434045   

[email protected]  
www.omniinstruments.co.uk

 

Australia / Asia Pacific Office 
Tel +61 (0)282 442 363 
Fax +61 (0)294 751 278

 

[email protected]

 

www.omniinstruments.com.au 

USA / Canada Office 
Tel +1-866-849-3441 
Fax +1-866-628-8055

 

[email protected]

 

www.omniinstruments.net

Содержание TR150

Страница 1: ...44 0 8700 434045 info omniinstruments co uk www omniinstruments co uk Australia Asia Pacific Office Tel 61 0 282 442 363 Fax 61 0 294 751 278 info omniinstruments com au www omniinstruments com au USA...

Страница 2: ...11 SHUNT CAL Button 11 PEAK Button 11 TROUGH Button 11 CONFIGURATION MENU Parameters 12 CALIBRATION MENU Parameters 14 Calibration Procedures 15 Specifications 17 Mechanical Dimensions 17 UK Europe O...

Страница 3: ...TR150 is powered by two internal non rechargeable AA alkaline batteries There is an option to have rechargeable alkaline batteries which can be charged without the need for removing them from the TR1...

Страница 4: ...PIN 4 ve Signal PIN 5 ve Charge Input RS232 Port Connections If the TR150 has been ordered with the optional RS232 output then this will be available via an 8 pin 723 series Binder connector The wiri...

Страница 5: ...ctions If this is performed at the end of the calibration procedure then a figure can be noted so the user can check calibration accuracy or connection integrity The button has to be held down to oper...

Страница 6: ...Et ZErO 0000000 SEt rAtE SEt OUEr SEt OPEr AutO OFF rS232 25 10 3 1 0 5 0000000 PSAVE 00 EnAbLEd RETURN TO NORMAL DISPLAY MODE UK Europe Office Tel 44 0 8700 434040 Fax 44 0 8700 434045 info omniinstr...

Страница 7: ...000000 dISP HI 0000000 donE tAbLE InPut LO 0000000 dISP LO 0000000 InPut HI 0000000 dISP HI 0000000 donE CAL VAL SEt 9Ain 0000000 SEt OFFS donE 0000000 UK Europe Office Tel 44 0 8700 434040 Fax 44 0 8...

Страница 8: ...mode When you choose to change the update rate you will be prompted whether you want to select 25Hz If you do not press You will then be prompted to select any of the other values which in order are 1...

Страница 9: ...tons to select a digit and the and buttons to increment or decrement the digits Press to accept the value and move onto the next parameter rS232 PRESS TO SKIP THIS PARAMETER AND EXIT MENU PRESS TO ENA...

Страница 10: ...ps of 0 005 The decimal point position is moved one place to the right each time you press the and together Any value can be entered for the resolution using the and buttons to select a digit and the...

Страница 11: ...down the button for 3 seconds It is also possible to set an Auto off value in the configuration menu so that the TR150 automatically switches itself off if there is no keyboard activity within a prese...

Страница 12: ...an idea of the calibration accuracy at a later date or for checking the integrity of the sensor and sensor cabling The shunt calibration resistor can be changed to suit specific requirements It is su...

Страница 13: ...in the display To remove the alarm the display value must be reduced to a value that is lower than that set in the SEt OVEr parameter This can be very useful as a safety feature or simply as a quick...

Страница 14: ...detected during the 25 minutes then the time period is restarted This can be a useful feature in a site environment should the TR150 be left unintentionally powered on rS232 Parameter This parameter...

Страница 15: ...e decimal point position one place to the right It also allows for the setting of the display resolution or the number of display counts the display changes with an input change To change the resoluti...

Страница 16: ...w stimulus applied to the sensor The value can be entered by using the and buttons to select a digit and the and buttons to change the digit When the value has been set press 6 You will then be prompt...

Страница 17: ...e and buttons to change the digit When the value has been set press 9 You will then be prompted with dISP HI Press to enter the display value required for the high input figure entered The value can b...

Страница 18: ...PEAK Enables peak hold TROUGH Enables valley trough hold Settable Parameters Tare Zero value display resolution decimal point position display update rate low power mode auto power off Mechanical Ele...

Отзывы: