18
2. Switch to input/output control, and select output [OUT].
3. Connect the leads to the mA terminals, as shown in Figure 10.
4. Enter the desired current using the keypad.
Figure 10. Connections for Sourcing Current
4.3-1 HART Resistor Selection
The PCL1200 can be set-up so that the 250 ohm resistor required for
Hart configuration devices resides inside the PCL1200. Enabling
the PCL1200's internal 250 ohm resistor eliminates the need to
manually add a series resistor during a Hart calibration process.
NOTE: When the PCL1200's internal 250 resistor is enabled,
maximum load driving capability drops from 1000 ohms @ 20mA to
750 ohms @20mA.
Enable/Disable Procedure
1. Remove the battery cover and remove the 2 screws that are
at the top of the case.
2. Remove the 2 screws on the bottom or lower portion of the
case.
3. Gently remove the top half of the case from the bottom.
4. Figure 10a. shows the location of the Hart jumpers.
®
®
®
®