OPERATING INSTRUCTIONS

USING THE IRT TO MEASURE TEMPERATURE

This section describes how to operate the OS730K in its “normal” mode, with and without use

of the backlight and/or laser pointer. In this mode (called 

REC

mode), each measurement made

by squeezing the measurement trigger is automatically stored (recorded) in a numerically

tagged location in the instrument’s nonvolatile memory. After 100 measurements are stored,

the 101st measurement made overwrites (erases) the first one. The section also explains how

to change the factory default temperature unit from °F to °C. 

1. Carefully remove the protective plastic film covering the LCD.
2. 

Power on the OS730K

by squeezing and holding the yellow measurement trigger 

(Fig. 1, Callout 3) while pointing the unit anywhere. The LCD and its gray backlight will

illuminate and the laser pointer will activate. (If none of these three things happen, the

IRT’s battery is dead and must be replaced; see p. 5 for instructions.) Note that squeezing

the trigger causes the word 

SCAN

(Fig. 2, Callout 1) to appear, flashing, in the upper left

corner of the LCD.

3. 

Release the trigger.

The following events will occur in a rapid-fire sequence:

I.   The unit will “chirp.”

II.  The word 

SCAN

will disappear and be replaced by the word 

HOLD

just below it.

III. The measured temperature will appear on the primary (large) readout in °F, with the 

text 

REC

at its lower left. 

REC

indicates that the measurement is about to be 

automatically stored (recorded) in the OS730K’s nonvolatile memory.

IV. The measured temperature will also appear on the secondary (smaller) readout,

following the brief appearance of a two-digit number. If this is the IRT’s first

measurement, that number will be 

01

. The number represents the measurement’s

memory storage location.

4. S

queeze and hold the trigger again 

while pointing the IRT at a different target. Then

release the trigger. As before, the unit will chirp and 

SCAN

will be replaced by 

HOLD

. The

temperature of the second target will again appear on both the primary and secondary

readouts. This time, however, note that the second reading will be accompanied by the

brief appearance of the memory tag 

02

on the secondary readout.

5. 

Squeeze and hold the trigger again

and then release it. The same sequence of events

will occur, with the new reading tagged 

03

in memory. Allow 30 seconds to pass. After 

30 seconds, the IRT’s Auto Power Off (APO) function will activate and cause the unit to

shut down silently.

To change the measurement unit from the factory default °F to °C

, press the 

MODE

button

(Fig. 1, Callout 7) once briefly while operating in 

REC

mode. 

REC

will be replaced by 

MAX

in

the middle of the LCD. Then press the 

°C/°F

button (Fig. 1, Callout 8). This will convert the

Fahrenheit readings on both readouts to the corresponding Celsius values.
To return to operation in 

REC

mode, press the 

MODE

button seven times with 

MAX

on-screen.

REC

will replace 

MAX

. The next section of the manual explains how to switch to operation in

the OS730K’s six display modes other than 

REC

and 

MAX

.

6

Содержание OS730K

Страница 1: ...OS730K 30 1 Ultra Wide Range IR Thermometer with K Port e mail info omega com For latest product manuals omegamanual info Shop online at omega comSM User sGuide MADE IN CHINA...

Страница 2: ...notice Servicing North America U S A Omega Engineering Inc One Omega Drive P O Box 4047 Stamford CT 06907 0047 USA Toll Free 1 800 826 6342 USA Canada only Customer Service 1 800 622 2378 USA Canada o...

Страница 3: ...30 1 ULTRA WIDE RANGE IR THERMOMETER WITH K PORT USER S MANUAL OS730K Please read this manual carefully and thoroughly before using this product...

Страница 4: ...using the thermometer The OS730K measures surface temperature using either of two methods non contact using an IR thermometer with a laser pointer or contact using a K type thermocouple A K type bead...

Страница 5: ...70nm Avoid looking directly at the laser pointer U S law prohibits pointing a laser beam at aircraft doing so is punishable by a fine of up to 10 000 and imprisonment The laser may cause discomfort if...

Страница 6: ...positions of all controls and connectors and the meaning of all display indications and icons before moving on to the Setup Instructions and Operating Instructions 1 Laser pointer 2 Infrared sensor 3...

Страница 7: ...STRUCTIONS INSTALL BATTERY The OS730K s battery compartment Fig 1 Callout 4 is below the measurement trigger and accessible from the front of the grip Before installing the 9V battery included in the...

Страница 8: ...rement is about to be automatically stored recorded in the OS730K s nonvolatile memory IV The measured temperature will also appear on the secondary smaller readout following the brief appearance of a...

Страница 9: ...ckly determine the hottest or coldest object of a group or the difference between their temperatures should be obvious These four display modes MAX MIN AVG and DIF can be entered from REC mode by pres...

Страница 10: ...its emissivity To maximize the accuracy of OS730K measurements you should enter the actual emissivity of the target surface see Appendix II using the instrument s three buttons and the procedure belo...

Страница 11: ...gins flashing you have 30 seconds to adjust its value up or down to any temperature within the unit s measurement range Press the C F button to decrease the value or the button to increase it To move...

Страница 12: ...alues associated with tags 85 and 86 would likely be irrelevant because they represent measurements made nearly 100 hundred trigger squeezes ago USING THE K TYPE PROBE TO MEASURE TEMPERATURE To measur...

Страница 13: ...g the OS730K take the average temperature of all objects within a circular target area Depending on the distance to the target the target area may include both the target and background objects in the...

Страница 14: ...g 1 Callout 2 often but never use a solvent Abrupt temperature changes will cause condensation and possible vapor penetration Clean the LCD after the vapor evaporates Blow off loose particles with cle...

Страница 15: ...the target All IR thermometers IRTs including the OS730K take the average temperature of all objects within a circular target area spot Although the distance D in the D S ratio is defined as a linear...

Страница 16: ...area at the measurement distance the following equation gives the average temperature of the target area Tavg Tmotor Tbackground 2 Solving for Tavg we get 200 75 2 or 137 5 F which is what the OS730K...

Страница 17: ...78 to 0 82 Concrete 0 95 Paint 0 80 to 0 95 Asbestos 0 95 Plastic 0 85 to 0 95 Ceramics 0 95 Paper 0 70 to 0 94 Brass 0 50 Plaster 0 80 to 0 90 Brick 0 90 Rubber 0 95 Carbon 0 85 Wood 0 90 Sludge 0 9...

Страница 18: ...per specification misapplication misuse or other operating conditions outside of OMEGA s control Components in which wear is not warranted include but are not limited to contact points fuses and triac...

Страница 19: ...bine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industri...

Отзывы: