SPECIFICATIONS 

Embedded microcontroller

Custom one-chip LSI device

Display type

Liquid-crystal with green backlight

Display size

2.05 x 1.5 in. (52 x 38mm)

Parameter measured

dB

Frequency range

31.5 Hz to 8 kHz

Measurement range

30 to 130 dB in autoranging mode; user can also select fixed

range of 30 to 80 dB, 50 to 100 dB, or 80 to 130 dB

Measurement weighting

By frequency and time; frequency weighing uses 

“A” or “C” standard; time weighting is fast or slow 

(200 ms or 500 ms response time)

Measurement accuracy

With “A” frequency weighting: ±3.5 dB @ 31.5 Hz, 

±2. 5 dB @ 63 Hz, ±2 dB @ 125 Hz, ±1.9 dB @ 250 Hz, 

±1.9 dB @ 500 Hz, ±1.4 dB @ 1 kHz, ±2.6 dB @ 2 kHz, 

±3.6 dB @ 4 kHz, ±5.6 dB @ 8 kHz

Measurement resolution

0.1 dB

Sampling time options

0, 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800 or 3600 seconds 

(0 seconds to 1 hour)

Settable parameters

Date, time, auto power off, beep sound, sampling time, 

decimal point or comma decimal division, “A” or “C” 

frequency weighting, fast or slow time weighting

Storable/recallable readings Maximum, minimum
SD card capacity

1 GB to 16 GB

Operating temperature

32º to 122ºF (0º to 50ºC)

Operating relative humidity 0 to 85%
Power source

6 Alkaline “AA”  batteries or optional 9-VDC AC adapter

Power consumption

8 mADC (normal operation, with backlight off and SD card not

saving data); 30 mADC with backlight on and card saving

data; 44 mADC with backlight on and card saving data

Dimensions of meter

9.65 x 2.68 x 1.77 in. (245 x 68 x 45mm)

Weight of meter 

1.08 lb. (489g)

10

Содержание HHSL402SD

Страница 1: ...HHSL402SD Sound Level Meter With Data Logging SD Card e mail info omega com For latest product manuals omegamanual info Shop online at omega com User sGuide MADE IN TAIWAN...

Страница 2: ...Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free...

Страница 3: ...Instructions 4 9 What s in the case 4 Setup 5 6 Calibrating the Meter 6 7 Normal Operation 7 8 Holding and Storing Measurements 8 Automatic vs Manual Datalogging 8 9 Transferring Data from the SD Car...

Страница 4: ...e storage capacities that SD memory cards offer Measurements can be made automatically at any sampling rate between one second and one hour After time stamping and storing the measurements on an SD ca...

Страница 5: ...16 Kickstand 1 17 Battery compartment cover 1 18 SD card socket OPERATING INSTRUCTIONS WHAT S IN THE CASE The HHSL402SD comes fully assembled in a hard carrying case along with a sound wind shield bal...

Страница 6: ...five seconds until the word dAtE appears in the center of the display y along with the flashing value 00 00 00 at the lower left above yy mm dd Set the current year by pressing the or button repeatedl...

Страница 7: ...8 Format the SD card Once the sampling time has been set and stored the term Sd F will appear in the lower half of the display Press the REC ENTER button Pressing the REC ENTER button causes the word...

Страница 8: ...ption 50 100 Press the button again and the display will show the third option 80 130 Press the REC ENTER button to select and store this range The shape of the A frequency weighting curve simulates t...

Страница 9: ...during the last recording session Pressing the REC ENTER button again briefly will make the term MIN appear to the right of REC and switch the display to the minimum value stored during the last sessi...

Страница 10: ...nge the storage location of manually logged data press the button once this causes the P to disappear from the left side of the display and the value on its line to begin flashing Once the flashing be...

Страница 11: ...B 2 kHz 3 6 dB 4 kHz 5 6 dB 8 kHz Measurement resolution 0 1 dB Sampling time options 0 1 2 5 10 30 60 120 300 600 1800 or 3600 seconds 0 seconds to 1 hour Settable parameters Date time auto power off...

Страница 12: ...tery indicator first appears Replacing the batteries requires removing the two screws that hold the battery compartment cover in place as explained in step 1 of the setup procedure After inserting fre...

Страница 13: ...herwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold b...

Страница 14: ...ors Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conduct...

Отзывы: