background image

5. Enable or disable auto power off

. Once the format of decimal point divisions has been

set and stored, the display will show the word “yES’ over the term “PoFF”. Press the 

or  button until the desired automatic power off management scheme (“yES” for

enable; “no” for disable) is displayed. Press the REC/ENTER button to store the selection.

If enabled, the power off function shuts off the HHSL402SD  after a period of inactivity of 

ten minutes. 

6. Enable or disable the beeper

. Once the auto power off function has been enabled or

disabled, the display will show the word “yES” over the word “bEEP”. Press the 

button until the desired setting (“yES” or “no”) is displayed, and then press the

REC/ENTER button to store the selection as the default. 

7. Set the datalogging sampling time

. Once the beeper has been enabled or disabled, the

display will show a value above the letters “SP-t”. Press the  or  button to decrease

or increase the value until the desired sampling time appears above “SP-t”. The options

are 0, 1, 2, 5, 10, 30, 60, 120, 300, 600, 1800 and 3600 seconds (0 seconds to 1 hour). 

8. Format the SD card

. Once the sampling time has been set and stored, the term “Sd-F”

will appear in the lower half of the display. Press the REC/ENTER button. 

Pressing the REC/ENTER button causes the word “no” or “yES” to appear over the term

“Sd-F”. Press the  button to make a selection. Choose “yES” whenever a new SD card is

being used, or when a used card is being repurposed (from use with another SD card

instrument or a camera, for example) and all data on it is to be erased. Choose “no” to

preserve any data on a card previously used with this instrument. 
If you choose “yES”, after you press the REC/ENTER button the instrument will prompt you

to confirm that decision by displaying the term “Ent” below “yES” and sounding three

beeps. To confirm that you want to begin the erasure/formatting procedure, press the

REC/ENTER button. “Ent” will then flash several times and the instrument will sound

another three beeps to confirm that the SD card has been erased and formatted. 
Once the SD card has been formatted (or not), the display will then either return to the first

of the six steps in the setup sequence—setting the current date and time—or show the

term “ESC”. If “ESC” appears, press the POWER/ESC button to exit the setup procedure and

enter normal operating mode. 

 

6

Содержание HHSL402SD

Страница 1: ...HHSL402SD Sound Level Meter With Data Logging SD Card e mail info omega com For latest product manuals omegamanual info Shop online at omega com User sGuide MADE IN TAIWAN...

Страница 2: ...Managed by the United Kingdom Office Toll Free 0800 466 342 TEL 33 0 161 37 29 00 FAX 33 0 130 57 54 27 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Toll Free...

Страница 3: ...Instructions 4 9 What s in the case 4 Setup 5 6 Calibrating the Meter 6 7 Normal Operation 7 8 Holding and Storing Measurements 8 Automatic vs Manual Datalogging 8 9 Transferring Data from the SD Car...

Страница 4: ...e storage capacities that SD memory cards offer Measurements can be made automatically at any sampling rate between one second and one hour After time stamping and storing the measurements on an SD ca...

Страница 5: ...16 Kickstand 1 17 Battery compartment cover 1 18 SD card socket OPERATING INSTRUCTIONS WHAT S IN THE CASE The HHSL402SD comes fully assembled in a hard carrying case along with a sound wind shield bal...

Страница 6: ...five seconds until the word dAtE appears in the center of the display y along with the flashing value 00 00 00 at the lower left above yy mm dd Set the current year by pressing the or button repeatedl...

Страница 7: ...8 Format the SD card Once the sampling time has been set and stored the term Sd F will appear in the lower half of the display Press the REC ENTER button Pressing the REC ENTER button causes the word...

Страница 8: ...ption 50 100 Press the button again and the display will show the third option 80 130 Press the REC ENTER button to select and store this range The shape of the A frequency weighting curve simulates t...

Страница 9: ...during the last recording session Pressing the REC ENTER button again briefly will make the term MIN appear to the right of REC and switch the display to the minimum value stored during the last sessi...

Страница 10: ...nge the storage location of manually logged data press the button once this causes the P to disappear from the left side of the display and the value on its line to begin flashing Once the flashing be...

Страница 11: ...B 2 kHz 3 6 dB 4 kHz 5 6 dB 8 kHz Measurement resolution 0 1 dB Sampling time options 0 1 2 5 10 30 60 120 300 600 1800 or 3600 seconds 0 seconds to 1 hour Settable parameters Date time auto power off...

Страница 12: ...tery indicator first appears Replacing the batteries requires removing the two screws that hold the battery compartment cover in place as explained in step 1 of the setup procedure After inserting fre...

Страница 13: ...herwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold b...

Страница 14: ...ors Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conduct...

Отзывы: