25
Name
Register Start
Address
Register
Count
Value type Value Units/
Description
Holding Registers
(read-write register addresses, read function byte 0x03,
write function byte 0x06 for single or 0x10 for multiple registers)
K-Factor
3000
2
32 Bit Float
Max Flowrate 3002
2
32 Bit Float
Flow Rate
Time Base
4000
1
Int
0 - Seconds
1 - Minutes
2 - Hours
3 - Days
Flow Rate
Volume Unit
4001
1
Int
0 - Pulses
1 - Ounces
2 - Gallons
3 - Barrels (Oil)
4 - Cubic Centimeters
5 - Cubic Meters
6 - Milliliters
7 - Liters
Max Flow
Time Base
4002
1
Int
0 - Seconds
1 - Minutes
2 - Hours
3 - Days
Max Flow
Volume Unit
4003
1
Int
0 - Pulses
1 - Ounces
2 - Gallons
3 - Barrels (Oil)
4 - Cubic Centimeters
5 - Cubic Meters
6 - Milliliters
7 - Liters
Total Volume
Units
4004
1
Int
0 - Pulses
1 - Ounces
2 - Gallons
3 - Barrels (Oil)
4 - Cubic Centimeters
5 - Cubic Meters
6 - Milliliters
7 - Liters
Содержание FPD-4000 Series