manualshive.com logo in svg
background image

Page - 10

While the System is Armed, and should it Trigger

While the security system is armed, the Status Light flashes red in color.

Should any intrusion attempt be detected, the system will instantly activate,
or "trigger".  Once triggered, the AL-1610-EDP loudly sounds the siren and
flashes the parking and interior lights on and off.

When it is first triggered, the Status Light changes its red flash pattern,

and the doors will automatically relock.  Should a door be open when the
system triggers, it will wait until the door is closed, and at that time relock
the doors.  The automatic relocking of the doors denies access to the thief,
and is just one of the many exclusive patented features of the AL-1610-
EDP.  The siren will sound and the parking and interior lights will flash for
30 seconds unless you disarm the system first (60, 90 and 120  seconds
activated periods are options- see Feature #11, page 34).  If all protected
entries are secure at the end of the 30 seconds, the system will stop and
rearm  itself, ready to detect further entry attempts.  If there is a protected
entry still open or the impact sensor still in a violated state at the end of 30
seconds, the system will reactivate for two more 30 second cycles. In this
case the system will stop after a total of 3 cycles and rearm automatically,
and then ignore only the open entry or violated sensor. When the entry is
closed or the sensor is reset, protection will begin instantly for the formerly
affected circuit.

Anytime the security system triggers, the Status Light will indicate which

protected zone triggered the system by flashing two, three or four times
between pauses, in the red color which indicates “alarm” operations. This
“Zone Violation” code will continue to flash, even after disarming. The
system can hold two different violation codes in it's memory, which is
cleared by turning the ignition switch "on".
Once the AL-1610-EDP has been activated and reset, the disarming
confirmation changes to make the user aware that it has done so (see the
following “Disarming the System” section).

you have these options: put the system into Alarm Valet Mode (page 19),
leave the door open, or, in most cases turning on the dome light may cause
the system to detect that your door is still open.  Leaving the ignition key
turned "on" is not recommended.

Last Door Arming offers a high level of security, since you do not have

to remember to arm the security system every time you leave the vehicle,
and using it may entitle you to an insurance discount (please check with
your agent or carrier).

Feature #15   Steady Siren or Pulsed Horn

Factory Default Setting

Steady Siren
(press “arm/lock” button to program)

Options:
Pulsed Horn Low

(press “disarm/unlock” button  to program)

Pulsed Horn Medium

(press 

||” bu

t

ton  to program)

Pulsed Horn High

(press red 

|||” 

b

utton  to program)

It is important to understand that the AL-1610-EDP has a primary audible
output, for the electronic siren; and that it also has a programmable relay
which among its applications is being used to sound the vehicle’s existing
horn.  This feature changes only the primary audible output, so that it can
be utilized to sound the existing horn by itself.  This is for cases when the
programmable relay is desired for other features, such as unlocking the
doors, or as an additional ignition or accessory output should it be needed
for the remote starting operation.

The Steady Siren setting is exactly that- a steady output which the

electronic siren requires.  When programming this feature for using the
output for the vehicle’s horn, the optional setting produce pulsed output on
the system’s siren wire, in three different pulse timings, which allow a de-
gree of customizing the horn’s sound during the alarm activation.

Page - 35

a system activation, or alarm, cannot occur.  This Arming Delay allows the
system to completely process its sensory parameters, which can include
allowing the vehicle to stabilize.  In some cases more time is needed than
the factory-set 3 seconds, and this feature offers three longer delay options.

Feature #16   Alarm Functions Bypass

Factory Default Setting

Off      (press “disarm/unlock” button to program)

Option:

On      (press “arm/lock” button to program)

This feature converts the system into a strictly Remote Keyless Entry Sys-
tem by eliminating all antitheft alarm-oriented operations and features.
When this feature is programmed on, the AL-1610-EDP has remote key-
less entry and engine starting operation only.

Feature #17   Ignition Activated Anti-Carjacking Protection

Factory Default Setting

Off      (press “disarm/unlock” button to program)

Option:

On      (press “arm/lock” button to program)

This form of Anti-Carjacking is initiated by the ignition key being turned on.
The Anti-Carjacking protection, and the three ways to initiate it are de-
scribed on pages 24 & 25.

Содержание Excalibur AL-1610-EDP

Страница 1: ...s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or theft of the vehicle or its contents or any incidental or cons...

Страница 2: ...doorlock U ON w doorlock 4 Starter Interrupt Functions Alarm only L Off U Automatic Alarm AntiGrind 5 Ignition Activated Override OFF U ON L 6 Doors Lock With Ignition On ON L OFF U 7 Doors Unlock Wi...

Страница 3: ...ect the engine has started running Feature 10 Gasoline Or Diesel Engine Factory Default Setting Gasoline press arm lock button to program Option Diesel press disarm unlock button to program This featu...

Страница 4: ...which keeps the engine running after removing the ignition key After exiting the user must then arm the system locking the vehicle doors by pressing the arm lock button Only after this is done will t...

Страница 5: ...rn Output press arm lock button to program Options Door Unlock press disarm unlock button to program Ignition Output press button to program Accessory Output press red button to program This is the se...

Страница 6: ...some newer vehicles Some newer vehicles require a double pulse output to remotely unlock the doors and or to disarm a factory equipped security system which is what the Double Pulse Unlock setting pr...

Страница 7: ...mable Features are accessed as the second level of features programming which is pressing the Valet Switch 10 times instead of 5 times when entering Programming Mode page 27 Caution These features hav...

Страница 8: ...tus Light flashes in the red color The system s reaction The parking and interior lights will flash once the siren will chirp once and the Status Light will begin to flash red confirming that the syst...

Страница 9: ...t 30 seconds the Last Door Arming process stops and will reset to start over when the point of entry is again closed All protected entries must be closed to initiate the Last Door Arming sequence To t...

Страница 10: ...not recommended Last Door Arming offers a high level of security since you do not have to remember to arm the security system every time you leave the vehicle and using it may entitle you to an insur...

Страница 11: ...isual disarming indications and Zone Violation code will remain this way until the ignition key is turned on Page 34 Feature 11 Alarm Duration Factory Default Setting 30 Seconds press arm lock button...

Страница 12: ...Step 3 Within 5 seconds press and release the Valet Switch one time The system will disarm Step 2 Using the ignition key turn the vehicle s ignition switch on The number of Valet Switch presses which...

Страница 13: ...Factory Default Setting Off press disarm unlock button to program Option On press arm lock button to program This feature allows an activated system to be overridden and disarmed by simply turning the...

Страница 14: ...tely stop it on demand before it times out again press and releasetogetherthetransmitter s arm lock and disarm unlock buttons The system will stop the engine and extinguish the parking lights This fea...

Страница 15: ...Omega AL 1610 EDP is installed into a manual transmission vehicle Installer Pro grammable Feature 5 must be turned on Then whenever remote start ing will be desired at a later time the following proce...

Страница 16: ...the engine running normally from the ignition switch have the gear selector in park and your foot off of the brake pedal Press the Valet Switch twice the parking lights will flash once and the siren...

Страница 17: ...tep 4 Within 10 seconds Press Release the Valet Switch the same number of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Vale...

Страница 18: ...m unlock and red buttons will activate the 5th channel Or if desired the transmitter button can be programmed by User Programming Feature 21 page 36 to operate any of these channels Page 18 To a large...

Страница 19: ...r optional controllers which are to operate the system at hand Turn the ignition on If the Unauthorized Transmitter Alert feature is on programming a transmitter or optional controller to the system w...

Страница 20: ...er AlertTM UTA is a protection feature which may be turned on by the user see the next section How to Program Transmitters Whenthisprotectionfeatureisutilized wheneveratransmitter or optional 2 way co...

Страница 21: ...Carjacking protection features whose operation may be selectively activated by the ignition by an open door or by the transmitter All three are programmable and must be turned on to operate Once acti...

Страница 22: ...smitters are programmed 6 2 Red Flashes pause 2 transmitters are programmed 9 2 Red Flashes Pause System was triggered by open hood or trunk 10 3 Red Flashes Pause System was triggered by an open door...

Отзывы: