Controller Functions
7.1
Modifying alarm thresholds
Selecting one or more absolute/ band alarms, it is possible to modify the alarm
thresholds directly by the user menu, without entering configuration.
AL . 1
kg
kg
000
6
.0
AL . 2
100.0
Sel
‹
‹
Press “Load data” to enter the thresholds
modification.
For the modification procedure refer to the following table:
Press
Display
Do
1 “Sel”
Selects the setpoint to be
modified.
Press “
n
” and “
m
” to modify
the value. Pressing “
” it
is possible to modify single
digit
2 “Sel”
Selects the next setpoint (if
activated), otherwise go to
point 3.
See point 1.
3 “Sel”
“
n
” and “
m
” disappear.
Press “Esc” to exit procedure.
7.2
Zero function, net/gross weight
kg
57
COM
0
Esc
TARE
These functions, enabled by the relevant
parameters during configuration, allow to
reset the measure or to switch from gross to
net weight and vieceversa. This window can
be entered by process visualization, pressing
one of the function keys.