VA Series Vapor Actuated Dial Thermometer

Specifications

Dial Sixes:

2", 2 

1

2

", 3 

1

2

", 4 

1

2

"

Dial:

Aluminum with white finish and black markings

Pointer:

Furnished standard adjustable

Movement:

Brass with precision gearing

Bourdon Tube:

Phosphor bronze

Accuracy:

Plus or minus one scale division

Case:

Stainless steel on all front flange and U-clamp models.
Back flange models in stainless (2"), black steel (3 

1

2

")

or Valox (4 

1

2

")

Process

Plain bulb, 

1

2

" NPT Union, 

1

2

" NPT sliding union 

Connection:

on 12 Connection: bendable extension, or thermowell.

Window:

Polycarbonate. Glass in 3 

1

2

" and 4 

1

2

" back flange

models

Bulb:

Stainless steel or nickel plated copper. Bulb O.D. 

7

16

(optional 

1

4

" O.D. x 2" length on -40 to 65°F range

only). Bulb lengths vary from 2" to 6" depending on
capillary length

Capillary:

Nickel plated copper, copper with bronze braid
armor, stainless steel, stainless steel with stainless
steel armor. Capillary lengths 1 to 100 feet (standard
length 5 feet)

Ranges:

Over twenty °F and °F/°C ranges available, from -40°
to +450°F

Applications:

Control panels, chemical processing, pipelines, food
processing, OEM applications, ovens, solar heating, 

Vapor actuated thermometers give excellent readings when
the bulb temperature is either above or below the
temperature of the indicating head. Avoid applications in
which the bulb and head are the same temperature
(ambient applications). If the bulb “crosses ambient” (i.e.,
goes from hotter than the indicating 

7

Содержание M1982/0902

Страница 1: ...capillary tube length Available Models Front Flange U Clamp Panel Mount Rear Flange Panel Mount Surface Mounted Figure 1 Case Style Installing the Vapor Actuated Thermometer Unpacking Instructions Rem...

Страница 2: ...ssary Case and Mounting Dimensions Front Flange U Clamp Rear Flange Panel Mount Panel Mount Surface Mount Figure 2 Case and Mounting Dimensions Installing the Indicating Head Surface Mount Rear Flange...

Страница 3: ...he front of the panel pass the bulb and capillary through the cutout 4 Affix the head to the panel 4a U clamp Model Tighten U clamp s against the back of your panel 4b Front Flange Model Screw the fla...

Страница 4: ...nections Tighten the thermometer to its fitting using a wrench applied to the hex or flats above the threads Never tighten by hand 1 Unscrew and remove the 1 2 NPT fitting using a 7 8 wrench 2 Screw t...

Страница 5: ...fitting with an 11 16 wrench Bendable Extensions I Place the bulb in the thermowell or directly in the process Use a thermowell whenever the bulb would be exposed to pressure fluid velocity or corros...

Страница 6: ...ing lenses which can be easily removed for field calibration To recalibrate your vapor actuated thermometer 1 Remove the thermometer from its fitting 2 Remove the lens 4 Immerse the bulb totally in an...

Страница 7: ...teel or nickel plated copper Bulb O D 7 16 optional 1 4 O D x 2 length on 40 to 65 F range only Bulb lengths vary from 2 to 6 depending on capillary length Capillary Nickel plated copper copper with b...

Страница 8: ...medical application used on humans or misused in any way OMEGA assumes no responsibility as set forth in our basic WARRANTY DISCLAIMER language and additionally purchaser will indemnify OMEGA and hol...

Отзывы: