![Omcan VP-CN-9200 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/omcan/vp-cn-9200/vp-cn-9200_instruction-manual_4165709010.webp)
10
Maintenance
Troubleshooting
CARE & CLEANING
1.
Always switch off and unplug the appliance and wait some minutes to let it cool down before cleaning.
2. Do not touch the heating bar or sealing bar shortly after operation.
3.
Always wipe off spilled liquids immediately. Do not spill or pour any liquids on or into the appliance or power
cable.
4.
Do not immerse the appliance, power cable or plug in water or any other liquid.
5. Do not place the appliance or power cable on wet surfaces to avoid risk of electric shock.
6. Do not use abrasives to clean the appliance or any part of it.
7. Clean the appliance immediately after each use to avoid that leftover food will stick to the heating bar.
8. Ensure not to damage the vacuum gaskets, heating bar and sealing bar when cleaning the appliance.
9. When disconnecting the power cable, do not pull the power cable, but always grasp the plugs.
10. Wipe the vacuum chamber, heating bar and sealing bar with a soft damp cloth. In the vacuum chamber
there are tiny holes used for sucking out the air, ensure not to spill any liquids into these holes.
11. To dry the vacuum gaskets, it is best to dab with a dry cloth to avoid damage.
12. Dry all parts thoroughly before you plug in and operate the appliance again.
13. Keep the upper lid of the appliance open when not in use.
THE VACUUM PUMP IS WORKING BUT THE BAG IS NOT VACUUMED, OR AIR FLOWS BACK INTO THE
VACUUMED BAG, OR THE BAG IS NOT SEALED
Possible Reasons
Possible Solutions
The bag is not positioned correctly.
The open end of the bag must reach into the vacuum chamber
completely. Additionally, ensure that the bag lays even and smooth
without any folds or gaps on the heating bar and vacuum gasket.
The bag is not airtight.
Use another bag.
Parts of the contents in the bag
perforate the bag during evacuation.
Remove sharp-edged items (e.g. bones) from the bag or turn the
edges inwards. Use another bag.
The vacuum gaskets on the lid and
base of the appliance are loose, not
clean, worn out, or damaged.
Carefully clean the vacuum gaskets using a soft damp cloth. If
the problem persists, send the appliance to an authorized service
centre for examination and repair.
The sealing time you have set is too
short or too high to make a good
sealing.
Adjust the seal time.
The appliance is overheated and/or
melting the bag.
Ensure that you have given the appliance enough time to cool
down. Wait 20 seconds between seals. Switch off the appliance
and with the lid open leave it cool down for 20 minutes.