10
Installation
b. Pull-out the converter from the cover.
c. Position of converter when using Propane(L.P.)
d. Install the converter cover to the regulator.
Note: The arrow in the regulator indicates the flow direction of the gas.
8. Re-install the U burners.
9. Check leakage and re-install other parts.
10.
Ignite the pilot burner and check flame state.
Turn the knobs to “High”.
If the U burner does not ignite, open the pilot valve more.
If the pilot flame appears larger than necessary, turn it down and reset burner ignition. The pilot flame should
be as small as possible but large enough to guarantee reliable ignition of the burners when the knobs are
turned to “
|
”.
Note: Please check leakage before re-install the control-panel.
GENERAL INSTALLATION INSTRUCTIONS
Ensure gas supply and gas type, as shown on unit nameplate, agree.