background image

 

 

www.microscopenet.com

 

 

- 4 -

2

 

Installation  

2.1  Installation of the binocular viewing head 

1)    Loosen the set screw on the top of the stand and remove the plastic cover on the top. 
2)    Remove the cap on the dovetail of the binocular viewing head. 
3)  Seat the dovetail of viewing head into the socket on the top of the stand and tighten 

the set screw. 

Caution

: Do not release the head from your hand grip until you are sure the head is 

installed securely. 

2.2  Installation of the eyepieces 

1)    Remove the protective caps from the eyepiece tubes. 
2)  Insert the eyepieces into the eyepiece tubes. 

2.3  Installation of the objectives 

1)    Adjust the coarse focus knob until the mechanical stage is at its lowest position. 
2)    Install the 4x objective into the nosepiece. Then in a clock-wise direction, rotate the 

nosepiece and install each succeeding higher magnification objective. 

Note: 

  Inspect the objectives frequently for dirt or oil; clean if necessary. 

  Use the 10X objective to initially focus the image of your specimen. 

  When changing the objective magnification, rotate the objective nosepiece until you 

hear a “click” sound. This ensures the objective is centered in the optical light path. 

2.4  Installation of the light filter 

1)  Swing out the filter holder which is located underneath the condenser. 

2)

  Insert the light filter into the holder, swing the holder back in.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

3

 

Operation 

Содержание M825

Страница 1: ...User Manual Binocular Compound Microscope Model M825 MicroscopeNet com...

Страница 2: ...Table of Contents i Caution 1 ii Care and Maintenance 2 1 Component Illustration 3 2 Installation 4 3 Operation 5 4 Specifications 7 5 Troubleshooting Guide 8...

Страница 3: ...ure or humidity and dusty environments Ensure that the microscope is located on a smooth level and firm surface 4 If any specimen solutions or other liquids splash onto the stage objective or any othe...

Страница 4: ...he optical surface use a soft cloth or cotton swab dampened with a lens cleaning solution available at camera stores All optical lenses should be swabbed using a circular motion A small amount of abso...

Страница 5: ...ece Tube 3 Diopter Ring 4 Viewing Head 5 Slide Holder 6 Stage 7 Condenser 8 Light Collector 9 Set Screw 10 Nosepiece 11 Objective 12 Stand 13 Coarse Focus Knob 14 Fine Focus Knob 15 Translation Knobs...

Страница 6: ...2 3 Installation of the objectives 1 Adjust the coarse focus knob until the mechanical stage is at its lowest position 2 Install the 4x objective into the nosepiece Then in a clock wise direction rot...

Страница 7: ...tive turn the 100X objective in position and rotate the focus stop lever clock wise all the way to the end so that the 100X objective will not contact the specimen while the stage is adjusted to its h...

Страница 8: ...m to 70 80 of the N A value of the respective objective will provide an image of acceptable quality If you want to observe the image of the iris diaphragm remove one eyepiece and look through the tube...

Страница 9: ...ves Achromatic 4X 10X 40X spring 100X spring oil Condenser Abbe NA 1 25 w iris aperture diaphragm and filter holder Rack and pinion adjustment Focus Mechanism Coaxial coarse and fine focusing knobs on...

Страница 10: ...d to the slide Attach a 0 17mm slide cover Slide cover is too thick or thin Use a slide cover of the appropriate thickness 0 17mm Slide may be upside down Turn slide over so the cover glass faces up P...

Страница 11: ...tensity control dial Aperture diaphragm closed too far Open to the proper setting Condenser position too low Position the condenser upward IMAGE PROBLEMS Problem Cause Solution Image will not focus wi...

Отзывы: