background image

 

 

www.microscopenet.com

 

 

- 7 -

 

Model  

M825  

Total Magnification   

40X, 64X, 100X, 160X, 400X, 640X, 1000X, 1600X   

Objective Tube Length   

160mm   

Viewing Head   

30º inclined, 360º swiveling Siedentopf binocular viewing head 
Interpupillary distance 55-75mm Adjustable diopter on right 
eyepiece tube   

Eyepieces   

1 pair of WF10X 1 pair of WF16X   

Nosepiece   

Reversed revolving quadruple   

Objectives   

Achromatic 4X, 10X, 40X(spring), 100X(spring, oil)   

Condenser  

Abbe, NA=1.25, w/ iris aperture diaphragm and filter holder 
Rack and pinion adjustment   

Focus Mechanism   

Coaxial coarse and fine focusing knobs on both sides w/ focus 
stop, tension adjustable   

Stage  

Double layer mechanical stage Dimension: 5-1/2” x 5-1/2” 
(140mmx140mm) Translation range: 3” x 2” (75mm X 50mm) 

Illumination   

Transmitted: 6V/20W Halogen, Variable intensity   

Power Supply   

AC 110V, 60HZ (US and Canada plug)   

Dimension   

12-1/2” x 11-1/2” x 15-3/4” (32cm x 29cm x 40cm)   

Net weight   

13 lb (6.34 kg)   

 
 

 

 

 

 

 

 

 

 

 

 

5

 

Troubleshooting Guide 

Содержание M825

Страница 1: ...User Manual Binocular Compound Microscope Model M825 MicroscopeNet com...

Страница 2: ...Table of Contents i Caution 1 ii Care and Maintenance 2 1 Component Illustration 3 2 Installation 4 3 Operation 5 4 Specifications 7 5 Troubleshooting Guide 8...

Страница 3: ...ure or humidity and dusty environments Ensure that the microscope is located on a smooth level and firm surface 4 If any specimen solutions or other liquids splash onto the stage objective or any othe...

Страница 4: ...he optical surface use a soft cloth or cotton swab dampened with a lens cleaning solution available at camera stores All optical lenses should be swabbed using a circular motion A small amount of abso...

Страница 5: ...ece Tube 3 Diopter Ring 4 Viewing Head 5 Slide Holder 6 Stage 7 Condenser 8 Light Collector 9 Set Screw 10 Nosepiece 11 Objective 12 Stand 13 Coarse Focus Knob 14 Fine Focus Knob 15 Translation Knobs...

Страница 6: ...2 3 Installation of the objectives 1 Adjust the coarse focus knob until the mechanical stage is at its lowest position 2 Install the 4x objective into the nosepiece Then in a clock wise direction rot...

Страница 7: ...tive turn the 100X objective in position and rotate the focus stop lever clock wise all the way to the end so that the 100X objective will not contact the specimen while the stage is adjusted to its h...

Страница 8: ...m to 70 80 of the N A value of the respective objective will provide an image of acceptable quality If you want to observe the image of the iris diaphragm remove one eyepiece and look through the tube...

Страница 9: ...ves Achromatic 4X 10X 40X spring 100X spring oil Condenser Abbe NA 1 25 w iris aperture diaphragm and filter holder Rack and pinion adjustment Focus Mechanism Coaxial coarse and fine focusing knobs on...

Страница 10: ...d to the slide Attach a 0 17mm slide cover Slide cover is too thick or thin Use a slide cover of the appropriate thickness 0 17mm Slide may be upside down Turn slide over so the cover glass faces up P...

Страница 11: ...tensity control dial Aperture diaphragm closed too far Open to the proper setting Condenser position too low Position the condenser upward IMAGE PROBLEMS Problem Cause Solution Image will not focus wi...

Отзывы: