400433D-EN
4 - 1
Chapter 4
Maintenance
Using the maintenance schedule in combination with the maintenance log provided in this chapter (page 4-
59) is important to ensure reliable equipment performance and accuracy. Typically, the frequency of most
maintenance activities is based upon the length of time that the equipment has been in operation; however,
harsher than normal environmental conditions can require that these activities be scheduled more frequently
than indicated in the table below.
Pump Maintenance
WARNING!
All pump maintenance activities must be performed by OMAX qualified personnel. Refer to
the OMAX Pump Service and Maintenance Guide for more detailed maintenance information.
General
Main Electric Motor Lubrication
The main electric motor is supplied with pre-lubricated ball bearing. The motor ball bearings should be
lubricated at intervals as follows:
Changing Crankcase Oil
To avoid excessive wear and damage to the crankcase bearings, it is important to change the crankcase oil
according to the intervals specified in the maintenance schedule. The oil must also be changed anytime it
becomes contaminated with water or other debris.
Always use SAE 30 (ISO 100) non-detergent motor oil. Use of other types of oil may shorten pump life. If the
temperature in the pump’s physical environment exceeds 90° F (32° C), use SAE 40 (ISO 150) non-
detergent motor oil. The crankcase holds two quarts (1.9 L) of oil.
Power End Maintenance Performed
Recommended Hours
Change oil, check belt tension
First 50, thereafter every 300
Clean white water tank, remove debris from filter screen
As required
Change water filters whenever the difference in pressure between the
inlet and outlet gauges is equal to, or larger than, 20 psi
Variable
Replace electrical enclosure air filters approximately once per month,
or more frequently as required
Variable
Nozzle Last Chance Filter
Weekly or whenever the nozzle is
removed for cleaning
Hours of Service Per Year
Recommended Relube Interval
Continuous
1 Year
Seasonal (Idle 6 months or more)
1 Year (beginning of season)
• Continuous, High Ambient Temperature
• Dirty or Moist Locations
• High Vibrations
6 Months
Содержание JetMachining Center 2626
Страница 8: ...OMAX JetMachining Center Operator s Guide viii 400433D EN ...
Страница 12: ...OMAX JetMachining Center Operator s Guide xii 400433D EN ...
Страница 22: ...OMAX JetMachining Center Operator s Guide Safety First 1 10 400433D EN ...
Страница 140: ...OMAX JetMachining Center Operator s Guide OMAX Glossary 6 16 400433D EN ...
Страница 144: ...OMAX JetMachining Center Operator s Guide Index 4 400433D EN ...