Siemens V20_EN_rev01-08032019.docx
10-9
10 PARAMETERS
10.1
DISPLAY PARAMETERS
Numbers prefixed with an "
r
" indicate that the parameter is a "read-only" parameter.
Numbers prefixed with a "
P
" indicate that the parameter is a "writable" parameter.
[index]
indicates that the parameter is an indexed parameter and specifies the range of indices available. If
the index is [0...2] and the meaning is not listed, then see "Data set".
.0 - 15
indicates that the parameter has several bits, which can be evaluated or connected individually.
10.2
INVERTER COMMISSIONING
All activities below described can be performed with the BOP.
The system is configured and is ready to be used. Is possible edit:
High speed
Low speed
Speed of releveling
Acceleration/deceleration ramps
Power limitation
ATTENTION: Only in case of change of the inverter or of the electric motor, you must do motor
recognition by P1900, before performing any calibration.
Please contact Omarlift Service, for the procedure.
10.3
PARAMETER LIST
Parameter
Description
STD VALUES
P 1900
Self-calibration of the motor perform between 20°C and 30°C in case
of motor change
-
P 1001
Upwards low speed
Min 20 Hz
P 1005
Upwards high speed
Max 50 Hz
P 1003
Releveling speed
Min 20 Hz
P 1007
Limited high speed for Ctrl
– power limitation
35 Hz
10.4
CONFIGURATION PARAMETERS
The inverter doesn’t handle the downward travel that is controlled and regulated by valve.
10.4.1
Upwards
During UPWARD travel the high speed coil on the valve must be always energized during the motor ON!
DI=INPUT
DO=OUTPUT