57
Plate voltage error
Check plate power supply
High voltage supply fault. Check the fuses on HV
board.
Grid voltage is low
Check grid power supply
Low voltage on the grid. Check fuse F4 on SW ON
board.
Screen voltage error
Check screen power supply
Check fuse F5 on HV supply board and fuse F1 on the
Screen board.
Amplifier is too hot
Check cooling system
Set up additional
blower
Check the airflow (ventilation grid on the rear panel).
Cooling exhaust must be free from any obstructions.
During extended use set the blower speed to ALWAYS
ON . (page 19)
HARD FAULT
Check HV circuits and Tube
Protection circuit saved HV against overload. If high
current from the HV supply caused the HARD FAULT
then protection is activated and the PA is automatically
switched OFF. Check HV circuits, blocking capacitors
and the tube itself.
Heating voltage error
Set up proper transformer
voltage selector
This error is usually due to improper setting of the
primary voltage on the transformer (page 34). In
normal condition Uf readings should be 8,5V to 9,3V.
Cooling error
Check blower rotation
Main blower problem. Check its functionality.
Mains error
Check mains voltage and set
up nominal mains voltage
Set up proper transformer
voltage selector
This error may be caused by the improper setting
of the nominal value of Um. Check your AC mains
voltage and set it as nominal Um (page 23).
Check the primary voltage setting on the
transformer. This fault may also be caused by
“soft” mains, when during transmitting the AC
voltage drops to a very low level.