26
Go to
SET EBS1 AUTO
and press
SET.
PA will automatically set 20mA of EBS.
You can try to do this manually, too.
Scroll to
SET EBS1 MANUAL
and press
SET.
Use up/down buttons to set 20mA or as close
as possible value and press
SAVE
.
Similar ways
EBS2
can be preprogrammed
(300mA by AUTO set).
Or another value of EBS2 by MANUAL Set.
Scroll to
CALIBRATION Ip, Is
and press
SET
.
Calibration will be done automatically.
Scroll to
SWR PROTECT
and press
SET.
This feature allows user to switch OFF the
SWR This feature allows the user to switch
OFF
the SWR protection.
We recommend to set it
ON
(SWR protection
circuit will stay active, max. allowed SWR is
3:1). If
OFF
is selected, higher SWR is
allowed, but reflected power is measured. If it
exceeds 350W, transmit will be blocked.
Press EXIT.
Type of supported TCVR and
working
frequency are visible on the display.
AUTO LED is ON.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.
Type of supported TCVR and working
frequency are visible on the display.
AUTO LED is ON.