Chapter 7 REMOTE Specifications
75
High definition LCD monitor OEV261H
Chapter 7 REMOTE Specifications
This monitor permits REMOTE operation via GPI input terminal.
7.1
GPI terminals
GPI screen items correspond to the following terminals. Use the REMOTE
CONFIG submenu to assign functions to each terminal (page 71).
The functions assigned to each terminal operate when GND (pin 5) is connected
(ON) or open (OFF).
Operating conditions
GPI input terminal (9P)
Pin number
Signal
1
GPI1
2
GPI2
3
GPI3
4
GPI4
5
GND
6
GPI5
7
GPI6
8
GPI7
9
GPI8
Level operation: Operates when GND is connected.
Edge operation: Operates when GND changes from open to connected or
from connected to open.
∗
If you have assigned a level operation function to more than one terminal,
the function operates as long as one of the terminals is connected. The
period between open and connected for edge operation should last longer
than 200 ms.
Assigned item
Function
Operating conditions
UNDEF
No setting (no function assigned)
–
PORT A SCAN SIZE MODE3
Switches PORT A scan size.
Level operation:
∗
4
Connected: MODE3, Open: OFF
PORT A SCAN SIZE MODE5
Switches PORT A scan size.
Level operation:
∗
4
Connected: MODE5, Open: OFF
PORT A SCAN SIZE MODE7
Switches PORT A scan size.
Level operation:
∗
4
Connected: MODE7, Open: OFF