background image

13

14

A wide lineup of UIS2 objectives.

Relief contrast equipment

Phase contrast equipment

This universal condenser for phase contrast and brightfield
observations offers excellent workability due to its long working
distance (73 mm) and compatibility with large containers: it can be
used in combination with 4X -40X phase contrast objectives. 
Phase contrast observation is also possible with 
the IX2-LWUCD condenser, whose working 
distance is 27 mm.

The Olympus Relief Contrast system provides a high contrast, 
3-D image similar to DIC for specimens mounted in plastic vessels.
Relief contrast is designed for use in cellular fertilization and making 
the nuclear envelope easier to see and penetrate.

Relief contrast equipment
* Unifies the shadow directions of each objective, improving
operability at all magnifications.
* A long working distance (45 mm) for the condenser (IX2-MLWCD)
doesn't bother the operation of the manipulator.

Two types of objectives for relief contrast are selectable: cost-
efficient Achromat models, or PlanSemiApochromat objectives with
high resolution and excellent focusing right up to the image
perimeters. Condenser (IX2-MLWCD) also supports DIC and phase
contrast observations for maximum flexibility.

The IX2-MLWCD equipes with optical component RC1 (for 10X objective), RC2 (for 20X objective),
RC3 (for 40X objective) and a polarizer to adjust the contrast.

PH

Special equipment for 
relief contrast and phase contrast.

Ultra long working distance condenser/IX-ULWCD

RC

RC

PH

RC/PH System

UIS2 Objectives

Mouse embryo 

Optical elements for 

Applicable objectives

IX2-MLWCD

IX2-MPHL

UPLFLN4XPH

IX2-MPHC

CPLFLN10XPH, CPLN10XPH, LCACHN20XPH

IX2-MPH1

LUCPLFLN20XPH

IX2-MPH2

LUCPLFLN40XPH, LCACHN40XPH, LUCPLFLN60XPH

Optical elements

Objectives

IX2-MDIC20

UPLSAPO20X, UPLFLN20X, LUCPLFLN20X

IX2-MDIC40

UPLSAPO40X2, UPLFLN40X, UPLFLN40XO* , 

LUCPLFLN40X

N.A.

W.D.

CPLN 10XRC 

*1

0.25

9.7 mm

LCACHN 20XRC 

*1

0.4

2.8 mm

LCACHN 40XRC 

*1

0.55

1.9 mm

CPLFLN 10XRC 

*1

0.3

9 mm

LUCPLFLN 20XRC 

*2

0.45

6.6 — 7.8 mm

LUCPLFLN 40XRC 

*2

0.6

3.0 — 4.2 mm

Achromat for
Relief 
Contrast

Plan Fluorite
for Relief
Contrast

Objectives for Relief Contrast observation

Phase contrast optical elements for IX2-MLWCD

and applicable objectives

DIC optical elements for IX2-MLWCD and

applicable objectives

*1 Objective with compensation for 1 mm plastic dish plus 0.5 mm

thick thermoplate

*2 Objective with compensation ring for 0~2 mm thick cover glass.

* Use with shift DIC slider (U-DICTS).

Model

N.A.

W.D.

F.N.

Cover glass

Immersion

Spring

Correction

Iris

Water proof &

(mm)

thickness (mm)

ring

diaphragm

oil proof function

UPLSAPO

UPLSAPO 4X

0.16

13

26.5

UPLSAPO 10X2

0.4

3.1

26.5

0.17

UPLSAPO 20X

0.75

0.6

26.5

0.17

_

UPLSAPO 20XO

0.85

0.2

26.5

Oil

_

UPLSAPO 40X2

0.95

0.18

26.5

0.11-0.23

_

_

UPLSAPO 60XW

1.2

0.28

26.5

0.13-0.21

Water

_

_

_

UPLSAPO 60XO

1.35

0.15

26.5

0.17

Oil

_

_

UPLSAPO 100XO

1.4

0.13

26.5

0.17

Oil

_

_

PLAPON

PLAPON 60XO

1.42

0.15

26.5

0.17

Oil

_

_

PLAPON 60XOSC

1.40

0.12

22

0.17

Oil

_

_

UPLFLN

UPLFLN 4X

0.13

17

26.5

UPLFLN 10X2

0.3

10

26.5

UPLFLN 20X

0.5

2.1

26.5

0.17

_

UPLFLN 40X

0.75

0.51

26.5

0.17

_

UPLFLN 40XO

1.3

0.2

26.5

0.17

Oil

_

_

UPLFLN 60X

0.9

0.2

26.5

0.11-0.23

_

_

UPLFLN 60XOI

1.25-0.65

0.12

26.5

0.17

Oil

_

_

_

UPLFLN 100XO2

1.3

0.2

26.5

0.17

Oil

_

_

UPLFLN 100XOI2

1.3-0.6

0.2

26.5

0.17

Oil

_

_

_

LUCPLFLN

LUCPLFLN 20X

0.45

6.6-7.8

22

0-2

_

LUCPLFLN 40X

0.6

2.7-4

22

0-2

_

LUCPLFLN 60X

0.7

1.5-2.2

22

0.1-1.3

_

LUCPLFLN 20XPH

0.45

6.6-7.8

22

0-2

_

LUCPLFLN 20XRC

0.45

6.6-7.8

22

0-2

_

LUCPLFLN 40XPH

0.6

3.0-4.2

22

0-2

_

LUCPLFLN 40XRC

0.6

3.0-4.2

22

0-2

_

LUCPLFLN 60XPH

0.7

1.5-2.2

22

0.1-1.3

_

UPLFLN-PH

UPLFLN 4XPH

0.13

17

26.5

UPLFLN 10X2PH

0.30

10

26.5

UPLFLN-PHP

UPLFLN 4XPHP

0.13

16.4

22

CPLFLN

CPLFLN 10XPH

0.3

9.5

22

1

CPLFLN 10XRC

0.3

9

22

1.5

LCACHN

LCACHN 20XPH

0.4

3.2

22

1

LCACHN 20XPHP

0.4

3.2

22

1

LCACHN 20XRC

0.4

2.8

22

1.5

LCACHN 40XPH

0.55

2.2

22

1

LCACHN 40XPHP

0.55

2.2

22

1

LCACHN 40XRC

0.55

1.9

22

1.5

CACHN & CPLN

CACHN 10XPHP

0.25

8.8

22

1

CPLN 10XPH

0.25

10

22

1

CPLN 10XRC

0.25

9.7

22

1.5

UAPON 340

UAPON 20XW340

0.70

0.35

22

0.17

Water

_

_

UAPON 40XO340

1.35

0.1

22

0.17

Oil

_

_

UAPON 40XW340

1.15

0.25

22

0.13–0.25

Water

_

_

_

TIRF

APON 60XOTIRF

1.49

0.1

22

0.13-0.19

Oil

_

_

UAPON 100XOTIRF

1.49

0.1

22

0.13-0.19

Oil

_

_

UAPON 150XOTIRF

1.45

0.08

22

0.13-0.19

Oil

_

_

All UIS2 objectives and WHN eyepieces: lead-free eco-glass.

UIS2 objectives 

Model

N.A.

W.D.

F.N

Cover glass

Immersion

Spring

Correction

Iris

Water proof &

(mm)

thickness (mm)

ring

diaphragm

oil proof cap

TIRFM

APO 100XOHR*

1.65

0.1

22

0.15

Oil

_

_

*Special cover glass and immersion oil required.

UIS objectives

Содержание IX71

Страница 1: ...Laboratory for genomic Reprogramming Head of Laboratory Riken Kobe Institute Center for Developmental Biology CDB P13 Yuji Abe M D Ph D The 1st Department of Obstetrics Gynecology School of Medicine...

Страница 2: ...wavelength range and flat high transmittance this new system sets a new world standard of fluorescence performance efficiently detecting even faint fluorescence signals without damaging the cell optim...

Страница 3: ...lar transmission in the near infrared range is significantly enhanced Overall performance all across the wavelength range is ideally suited for today s most demanding research applications High N A ob...

Страница 4: ...put output of a parallel pencil of rays and the multiple port structure for gaining the primary image are designed internally in the form of tiers To maximize the possible wavelength width the optical...

Страница 5: ...filter wheels on the excitation and emission sides However this kind of mirror encounters the problem that each fluorescence image gets darker as the number of color dyes increase because the transmi...

Страница 6: ...g adapter U DULHA Allows simultaneous attachment of two light sources such as halogen and mercury Selection mirror is replaceable for custom applications Fluorescence illumination light source Reflect...

Страница 7: ...DICT U DICTS Thin specimen Big shearing value Thick specimen Small shearing value 10X 40X 100X U DICTHC for superior contrast with thin specimen observation U DICTHR for superior resolution with thic...

Страница 8: ...s DIC optical elements for IX2 MLWCD and applicable objectives 1 Objective with compensation for 1 mm plastic dish plus 0 5 mm thick thermoplate 2 Objective with compensation ring for 0 2 mm thick cov...

Страница 9: ...ffers different magnification without switching the objective lens 1 6X is standard IX71 81 and 2 0X is optional In addition to maximizing rigidity of IX2 microscope frame Olympus simplified or shorte...

Страница 10: ...pen close and camera vs visual observation Parfocal compensation function among objectives This function allows the focus point to be matched from low to high magnification objectives Refocusing each...

Страница 11: ...e cell injection Built in stage warming plate Objective heater 5 CO2 supply tube with 4 outer diameter 2 inner diameter and 400 mm length Not available in some areas Thermoplate MATS series This therm...

Страница 12: ...llumination with twin scanners TIRFM Total Internal Reflection Fluorescence Microscopy Since 1997 Olympus has been a market leader in objective based Total Internal Reflection microscope that allows a...

Страница 13: ...system from an arc lamp source ARC EVA SYSTEM DIAGRAM Main specifications Microscope Research inverted system microscope IX71 Fluorescence Arc illumination total internal reflection illuminator fluor...

Страница 14: ...order Easy system upgrade by attaching double lamphouse illuminator IX2 RFAW to IX2 series inverted microscope Photoactivation illuminator for inverted microscopy The novel Kaede gene is useful in bi...

Страница 15: ...urret IX2 RFAC 6 positions in a rotating turret built in shutter Light source 100 W Hg lamp housing and transformer or 75 W Xe lamp housing and transformer IX71 specifications Microscope body Revolvin...

Страница 16: ...tage IX SUSP Stage plate Incubator IX2 KSP Narrow plain stage CK2 SS Side stage U SIP Split primary image camera port Cube cassette for full image split images U IFFH Focus handle Interface U ZPCB2 Z...

Отзывы: