Confocal laser scanning microscope/
FLUOVIEW FV1000 system

The Fluoview/FV1000 is a next-generation imaging system
designed for high-resolution, confocal observation of both fixed and
live cells. The FV1000 offers advances in confocal system
performance while providing the speed and sensitivity required for
live cell imaging with minimal risk of damage to living specimens.
In addition, the FV1000 offers a revolutionary synchronized laser
scanning system called the SIM Scanner.
While one laser stimulates, the second laser
simultaneously provides high resolution
imaging. This coordination of laser
stimulation and imaging makes the FV1000
an ideal choice for FRAP, 
FLIP and photoactivation.

* FV1000 is a class 3B laser product.

22

21

Manipulator

Manipulating cells.

Micromanipulation system/ON3

Olympus' original micromanipulator offers high stability and
excellent stability because of its compact body. Motorized coarse
and oil hydraulic fine three axes operation are designed in its
compact and rigid body with hanging down ergonomic joystick
control. ON3 micromanipulator is securely fixed through the screw
holes on IX2 microscope frame.

ON3-99D

ON3-99D with return mechanism (UT-R)

Manual combination 
(ONM-2D+ONO-301D+UT-D)

Manual combination with return mechanism
(ONM-2D+ONO-301D+UT-D+UT-R)

Human embryo

Images of Kaede-expressed cells demonstrating
the photoactivation acquired every 300 msec and
observed via 405 blue diode laser illumination with
twin scanners.

TIRFM 
(Total Internal Reflection Fluorescence
Microscopy)

Since 1997, Olympus has been a market leader in objective based
Total Internal Reflection microscope that allows an evanescent
wave illumination approximately 200 nm into the specimen beyond
the coverglass interface. Olympus extends that leadership role by
offering four objectives for TIRFM including the world's highest N.A.
objective, the 100X N.A. 1.65 objective.
The incredibly thin optical section created be TIRFM allows an
extremely high signal to noise image to be collected. Popular
applications include vesicle tracking, cellular adhesions and single
molecule events.

• Olympus' original high N.A. objectives make it easy to produce an
evanescent wave field. So little light is leaked that a high-contrast
image can be obtained against a dark background.

N.A. 1.65, 100X objective (APO100XOHR)
(Use special cover glass and immersion oil)

N.A. 1.49, 60X objective (APON60XOTIRF)
(Use normal cover glass and immersion oil)

N.A. 1.49, 100X objective (UAPON100XOTIRF)
(Use normal cover glass and immersion oil)

N.A. 1.45 150X objective (UAPON150XOTIRF)
(Use normal cover glass and immersion oil)

• Once the initial alignment of the laser
optical path is set, it is just simple operation
switching between TIRF and widefield
illumination.

* TIRFM is a class 3B laser product.

Ultra-sensitive fluorescence microscopy.

Micrometer

TIRFM

Total Internal Reflection Fluorescence
observation with evanescent wave excitation

Widefield fluorescence observation with 
mercury arc lamp excitation

Simultaneous laser light stimulation and imaging.

Laser Scanning Confocal

Application System

Содержание IX71

Страница 1: ...Laboratory for genomic Reprogramming Head of Laboratory Riken Kobe Institute Center for Developmental Biology CDB P13 Yuji Abe M D Ph D The 1st Department of Obstetrics Gynecology School of Medicine...

Страница 2: ...wavelength range and flat high transmittance this new system sets a new world standard of fluorescence performance efficiently detecting even faint fluorescence signals without damaging the cell optim...

Страница 3: ...lar transmission in the near infrared range is significantly enhanced Overall performance all across the wavelength range is ideally suited for today s most demanding research applications High N A ob...

Страница 4: ...put output of a parallel pencil of rays and the multiple port structure for gaining the primary image are designed internally in the form of tiers To maximize the possible wavelength width the optical...

Страница 5: ...filter wheels on the excitation and emission sides However this kind of mirror encounters the problem that each fluorescence image gets darker as the number of color dyes increase because the transmi...

Страница 6: ...g adapter U DULHA Allows simultaneous attachment of two light sources such as halogen and mercury Selection mirror is replaceable for custom applications Fluorescence illumination light source Reflect...

Страница 7: ...DICT U DICTS Thin specimen Big shearing value Thick specimen Small shearing value 10X 40X 100X U DICTHC for superior contrast with thin specimen observation U DICTHR for superior resolution with thic...

Страница 8: ...s DIC optical elements for IX2 MLWCD and applicable objectives 1 Objective with compensation for 1 mm plastic dish plus 0 5 mm thick thermoplate 2 Objective with compensation ring for 0 2 mm thick cov...

Страница 9: ...ffers different magnification without switching the objective lens 1 6X is standard IX71 81 and 2 0X is optional In addition to maximizing rigidity of IX2 microscope frame Olympus simplified or shorte...

Страница 10: ...pen close and camera vs visual observation Parfocal compensation function among objectives This function allows the focus point to be matched from low to high magnification objectives Refocusing each...

Страница 11: ...e cell injection Built in stage warming plate Objective heater 5 CO2 supply tube with 4 outer diameter 2 inner diameter and 400 mm length Not available in some areas Thermoplate MATS series This therm...

Страница 12: ...llumination with twin scanners TIRFM Total Internal Reflection Fluorescence Microscopy Since 1997 Olympus has been a market leader in objective based Total Internal Reflection microscope that allows a...

Страница 13: ...system from an arc lamp source ARC EVA SYSTEM DIAGRAM Main specifications Microscope Research inverted system microscope IX71 Fluorescence Arc illumination total internal reflection illuminator fluor...

Страница 14: ...order Easy system upgrade by attaching double lamphouse illuminator IX2 RFAW to IX2 series inverted microscope Photoactivation illuminator for inverted microscopy The novel Kaede gene is useful in bi...

Страница 15: ...urret IX2 RFAC 6 positions in a rotating turret built in shutter Light source 100 W Hg lamp housing and transformer or 75 W Xe lamp housing and transformer IX71 specifications Microscope body Revolvin...

Страница 16: ...tage IX SUSP Stage plate Incubator IX2 KSP Narrow plain stage CK2 SS Side stage U SIP Split primary image camera port Cube cassette for full image split images U IFFH Focus handle Interface U ZPCB2 Z...

Отзывы: