background image

3

Superior S/N ratio delivers imaging excellence

UIS2 objectives' fluorescence S/N ratio is improved by using
selected low fluorescence glass material, and minimized
autofluorescence obtained by anti-reflection coating and cementing
material. Also numerical aperture (N.A.) has improved in addition to
the reduction of autofluorescence. Weak fluorescence emissions
are efficiently detected even from weak excitation light, which is
friendly for the living cell. 
The ideal fluorescence imaging of live cells with the UIS2 systems!

High transmittance UPLSAPO100XO

T

ransmittance(%)

Wavelength (nm)

0

300

400

500

600

700

800

10

20

30

40

50

60

70

80

90

100

(new) UPLSAPO100XO

(conventional) PLAPO100XO

Focus (

µ

m)

Wavelength (nm)

Comparing chromatic aberration compensation levels: 

(The smaller the figure the better)

UPLSAPO series chromatic aberration compensation 

-0.5

0

400

450

500

550

600

650

700

750

800

850

900

0.5

1

1.5

2

(new) UPLSAPO100XO

(conventional) UPLAPO100XO

Alexa Fluor488 

Cy7 

UIS2 optics are designed to maximize S/N ratio and optical
performance for live cell fluorescence imaging.

High transmittances over a wider 
wavelength range

UIS2 objective for the IX71/81 achieves flat, high transmittance from
visible to near-infrared light, thanks to new UW multi-coating which
effectively cuts reflection over the super wide band spectrum. In
particular, transmission in the near infrared range is significantly
enhanced. Overall, performance all across the wavelength range is
ideally suited for today's most demanding research applications.

High N.A. objectives for fluorescence imaging

PLANAPO60XO and UPLSAPO100XO have outstanding N.A., 1.42
and 1.4 respectively, suitable for fluorescence imaging and bright-
field observation as well. In addition to their high fluorescence S/N
ratio, both these lenses are able to handle UV excitation light. The
UPLSAPO100XO provides a transmission of down to 340 nm.

Aspherical collector lens provides
excellent excitation efficiency.

Unique, optional ring slit
illumination reduces
objective autofluorescence.

Objectives providing 
the best fluorescence
S/N ratios.

High performance mirror units
optimized for fluorescence.

Stray light reduction to
absorb spurious reflections
from dichromatic mirror.

4

Effective compensation for 
chromatic aberration up to near-infrared

The UPLSAPO series is the highest class UIS2 objectives, whose
super apochromatic features effectively compensate for chromatic
aberration from the visible spectrum all the way to near IR. This
means that just one objective covers imaging from UV to IR range. 
The series also offers outstanding image clarity without color shift
for multi-color observations using fluorochromes covering a wide
wavelength spectrum.

UPLSAPO100XO

Cy7

Wavelength:

767 nm

Alexa

Fluor488

Wavelength:

519 nm

UPLAPO100XO

Objective:
UPLSAPO100XO

Mirror unit:
U-MNIBA3

Objective:
UPLAPO100XO

Mirror unit:
U-MNIBA2

Содержание IX71

Страница 1: ...Laboratory for genomic Reprogramming Head of Laboratory Riken Kobe Institute Center for Developmental Biology CDB P13 Yuji Abe M D Ph D The 1st Department of Obstetrics Gynecology School of Medicine...

Страница 2: ...wavelength range and flat high transmittance this new system sets a new world standard of fluorescence performance efficiently detecting even faint fluorescence signals without damaging the cell optim...

Страница 3: ...lar transmission in the near infrared range is significantly enhanced Overall performance all across the wavelength range is ideally suited for today s most demanding research applications High N A ob...

Страница 4: ...put output of a parallel pencil of rays and the multiple port structure for gaining the primary image are designed internally in the form of tiers To maximize the possible wavelength width the optical...

Страница 5: ...filter wheels on the excitation and emission sides However this kind of mirror encounters the problem that each fluorescence image gets darker as the number of color dyes increase because the transmi...

Страница 6: ...g adapter U DULHA Allows simultaneous attachment of two light sources such as halogen and mercury Selection mirror is replaceable for custom applications Fluorescence illumination light source Reflect...

Страница 7: ...DICT U DICTS Thin specimen Big shearing value Thick specimen Small shearing value 10X 40X 100X U DICTHC for superior contrast with thin specimen observation U DICTHR for superior resolution with thic...

Страница 8: ...s DIC optical elements for IX2 MLWCD and applicable objectives 1 Objective with compensation for 1 mm plastic dish plus 0 5 mm thick thermoplate 2 Objective with compensation ring for 0 2 mm thick cov...

Страница 9: ...ffers different magnification without switching the objective lens 1 6X is standard IX71 81 and 2 0X is optional In addition to maximizing rigidity of IX2 microscope frame Olympus simplified or shorte...

Страница 10: ...pen close and camera vs visual observation Parfocal compensation function among objectives This function allows the focus point to be matched from low to high magnification objectives Refocusing each...

Страница 11: ...e cell injection Built in stage warming plate Objective heater 5 CO2 supply tube with 4 outer diameter 2 inner diameter and 400 mm length Not available in some areas Thermoplate MATS series This therm...

Страница 12: ...llumination with twin scanners TIRFM Total Internal Reflection Fluorescence Microscopy Since 1997 Olympus has been a market leader in objective based Total Internal Reflection microscope that allows a...

Страница 13: ...system from an arc lamp source ARC EVA SYSTEM DIAGRAM Main specifications Microscope Research inverted system microscope IX71 Fluorescence Arc illumination total internal reflection illuminator fluor...

Страница 14: ...order Easy system upgrade by attaching double lamphouse illuminator IX2 RFAW to IX2 series inverted microscope Photoactivation illuminator for inverted microscopy The novel Kaede gene is useful in bi...

Страница 15: ...urret IX2 RFAC 6 positions in a rotating turret built in shutter Light source 100 W Hg lamp housing and transformer or 75 W Xe lamp housing and transformer IX71 specifications Microscope body Revolvin...

Страница 16: ...tage IX SUSP Stage plate Incubator IX2 KSP Narrow plain stage CK2 SS Side stage U SIP Split primary image camera port Cube cassette for full image split images U IFFH Focus handle Interface U ZPCB2 Z...

Отзывы: