background image

• OLYMPUS CORPORATION is ISO14001 certified.
• OLYMPUS CORPORATION is FM553994/ISO9001 certified.
• OLYMPUS CORPORATION is MD540624/ISO13485 certified.

• Illumination devices for microscope have suggested lifetimes.    
  Periodic inspections are required. Please visit our web site for details.

• Windows is a registered trademark of Microsoft Corporation in the United States and other countries. 
  All other company and product names are registered trademarks and/or trademarks of their  
   respective owners.
• Images on the PC monitors are simulated.
• Specifications and appearances are subject to change without any notice or obligation on the part of  
   the manufacturer.

Photos courtesy of:

Atsushi Miyawaki M.D., Ph.D, Ms. Asako Sakagami,  RIKEN Brain Science Institute Laboratory for Cell Function Dynamics (P8)
Teruhiko Wakayama, Ph.D., Laboratory for genomic Reprogramming, Head of Laboratory, Riken Kobe Institute, Center for Developmental Biology (CDB) (P13)
Yuji Abe M.D.Ph.D., The 1st Department of Obstetrics & Gynecology School of Medicine, Toho University (P21)
Atsushi Miyawaki M.D., Ph.D, Ms. Ryoko Ando, RIKEN Brain Science Institute Laboratory for Cell Function Dynamics (P22, P26)
Atsushi Miyawaki M.D., Ph.D, Mr. Hideaki Mizuno, RIKEN Brain Science Institute Laboratory for Cell Function Dynamics (P25)
Tohru Murakami, M.D., Ph.D, Department of Neuromuscular and Developmental Anatomy, Gunma University Graduate School of Medicine (P23 above, zebra fish)
Dr. Takeshi Awasaki and Dr. Kei Ito, Institute of Molecular and Cellular Biosciences, The University of Tokyo (P23 below, drosophia)
Dr. Kazuo Kurokawa, Department of tumor virology, Research institute for microbial diseases, Osaka university (P24 below, Kaede-Crk II protein expressed in a HeLa cell)

Research 

Inverted System Microscope

IX71/IX81

IX2 Series

Built for Live Cell Imaging

Printed in Japan M1539E-0610B

Содержание IX71

Страница 1: ...Laboratory for genomic Reprogramming Head of Laboratory Riken Kobe Institute Center for Developmental Biology CDB P13 Yuji Abe M D Ph D The 1st Department of Obstetrics Gynecology School of Medicine...

Страница 2: ...wavelength range and flat high transmittance this new system sets a new world standard of fluorescence performance efficiently detecting even faint fluorescence signals without damaging the cell optim...

Страница 3: ...lar transmission in the near infrared range is significantly enhanced Overall performance all across the wavelength range is ideally suited for today s most demanding research applications High N A ob...

Страница 4: ...put output of a parallel pencil of rays and the multiple port structure for gaining the primary image are designed internally in the form of tiers To maximize the possible wavelength width the optical...

Страница 5: ...filter wheels on the excitation and emission sides However this kind of mirror encounters the problem that each fluorescence image gets darker as the number of color dyes increase because the transmi...

Страница 6: ...g adapter U DULHA Allows simultaneous attachment of two light sources such as halogen and mercury Selection mirror is replaceable for custom applications Fluorescence illumination light source Reflect...

Страница 7: ...DICT U DICTS Thin specimen Big shearing value Thick specimen Small shearing value 10X 40X 100X U DICTHC for superior contrast with thin specimen observation U DICTHR for superior resolution with thic...

Страница 8: ...s DIC optical elements for IX2 MLWCD and applicable objectives 1 Objective with compensation for 1 mm plastic dish plus 0 5 mm thick thermoplate 2 Objective with compensation ring for 0 2 mm thick cov...

Страница 9: ...ffers different magnification without switching the objective lens 1 6X is standard IX71 81 and 2 0X is optional In addition to maximizing rigidity of IX2 microscope frame Olympus simplified or shorte...

Страница 10: ...pen close and camera vs visual observation Parfocal compensation function among objectives This function allows the focus point to be matched from low to high magnification objectives Refocusing each...

Страница 11: ...e cell injection Built in stage warming plate Objective heater 5 CO2 supply tube with 4 outer diameter 2 inner diameter and 400 mm length Not available in some areas Thermoplate MATS series This therm...

Страница 12: ...llumination with twin scanners TIRFM Total Internal Reflection Fluorescence Microscopy Since 1997 Olympus has been a market leader in objective based Total Internal Reflection microscope that allows a...

Страница 13: ...system from an arc lamp source ARC EVA SYSTEM DIAGRAM Main specifications Microscope Research inverted system microscope IX71 Fluorescence Arc illumination total internal reflection illuminator fluor...

Страница 14: ...order Easy system upgrade by attaching double lamphouse illuminator IX2 RFAW to IX2 series inverted microscope Photoactivation illuminator for inverted microscopy The novel Kaede gene is useful in bi...

Страница 15: ...urret IX2 RFAC 6 positions in a rotating turret built in shutter Light source 100 W Hg lamp housing and transformer or 75 W Xe lamp housing and transformer IX71 specifications Microscope body Revolvin...

Страница 16: ...tage IX SUSP Stage plate Incubator IX2 KSP Narrow plain stage CK2 SS Side stage U SIP Split primary image camera port Cube cassette for full image split images U IFFH Focus handle Interface U ZPCB2 Z...