background image

923650001_90_004 

 

DESCRIPTION  

With Olympia Electronics emergency lighting 
addressable panel GR-6500, the light system 
becomes more optimal, simple and provides the 
user valuable information, not only for the entire 
network, but also for each luminaire individually. 
The ease of access of GR-6500 helps you to 
retrieve information and control the system light 
network with simple actions as well as remotely 
via Ethernet.  
Our software application makes things way more 
simple. You create the plan, you set up each 
luminaire and zone according to your needs and 
eventually you upload the whole plan via USB 
cable. 

 

PRODUCTS 
-

 GR-6500   250 devices. 16 Zones. 

 

SPECIFICATIONS

 

Dimensions: 322 x 241 x 97 mm 
Weight : < 2Kg (Without battery) 
Input Power: 230VAC, 50-60Hz, <25W 
Operating Temperature: 5

° 

40°C (41°F –

 

104°F)

 

Degrees of cover protection : IP30 

 

CAUTION 

This product may only be installed or 

maintained by a qualified Electrician. 

The system must be installed in accordance 

with national regulations and requirements. 

-

 All power must be disconnected before 

installation or maintenance. 

Only original spare parts must be used for this 

product. 

The panel is compatible only with the 

corresponding Olympia Electronics addressable 
luminaires. 

 

 

 

NEEDED MATERIALS 

Mounting Hardware. 

Screwdrivers 

Multi-meter 

Pliers

 

Cutter 

 

MAINTENANCE

 

The periodical checks must follow the EN50172 
or be verified according to local regulations. 

WARRANTY 

Olympia Electronics guarantees the quality, 
condition and operation of the goods. The 
period of warranty is specified in the official 
catalogue of Olympia Electronics and also in the 
technical leaflet, which accompanies each 
product. This warranty ceases to exist if the 
buyer does not follow the technical instructions 
included in official documents given by Olympia 
Electronics or if the buyer modifies the goods 
provided or has any repairs or re-setting done by 
a third party, unless Olympia Electronics has fully 
agreed to them in writing. Products that have 
been damaged can be returned to 
the premises of our company for repair or 
replacement, as long as the warranty period is 
valid. Olympia Electronics reserves the right to 
repair or to replace the returned goods and to or 
not charge the buyer depending on the reason 
of defection. Olympia Electronics reserves the 
right to charge or not the buyer the 
transportation cost. 
 

CONTACT  DETAILS 

72nd km. O.N.R. Thessaloniki-Katerini 
P.C. 60300 P.O. Box 06 

Ε

ginio Pierias Greece 

www.olympia-electronics.gr 

[email protected]

 

Tel. +30 23530 51200 

 

 

 

Содержание GR-6500

Страница 1: ...1 923650001_90_004 Emergency lighting addressable panel GR 6500 Quick Installation Guide Generic Design LIGHTING ADR...

Страница 2: ...h the corresponding Olympia Electronics addressable luminaires NEEDED MATERIALS Mounting Hardware Screwdrivers Multi meter Pliers Cutter MAINTENANCE The periodical checks must follow the EN50172 or be...

Страница 3: ...500 can support up to 250 points The maximum connected points to each LOOP must not exceed the 150 Each point must have unique non repeatable address No arithmetic address sequence is obligatory Keep...

Страница 4: ...and no additional unused conductors Select shielded cable for every installation The cable shield must be reconnected in every cut during the length of the loop and must be terminated to the PE Power...

Страница 5: ...opology Note Max 250points in total Point 1 Point 2 Point 3 Point 4 Point 5 L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L L Z 1A Z 1B Point Point Point Point Point Poin...

Страница 6: ...st Connect the each zone to the corresponding output of the panel Connect the monitoring Relays Optional Connect the 12V 7Ah Lead Acid battery with the correct polarity ACTIVATION Make sure there is n...

Страница 7: ...et through the panel connecting and setting the luminaires one by one ADDRESSING LUMINAIRES TECHNICIAN MENU SETTINGS CHANGE ADDRESS POINT Note It is not required to connect the 230VAC power on the lum...

Страница 8: ...the panel TECHNICIAN MENU POINTS Assign a Zone for each point Optional TECHNICIAN MENU Program FUNCTION TEST TECHNICIAN MENU Program CAPACITY TEST TECHNICIAN MENU NETWORK Set ETHERNET PCB Enable or Di...

Страница 9: ...Verify the specifications of the communication cable THE PANEL REPORTS POINT LAMP BATTERY FAULT As mentioned the error comes from either an unconnected battery or a lamp led error Inspect for probabl...

Страница 10: ...o the address where the problem is By repairing the connection problem on point we can now see only GOOD packets increasing we can see the name of the luminaire as well as the battery voltage and char...